IEC 61076-3-104:2017
Current
The latest, up-to-date edition.
Connectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, English
05-22-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Technical information
4 Dimensional information
5 Characteristics
6 Test schedule
Annex A (normative) - Gauging procedure
Annex B (normative) - Locking device mechanical
operation - test procedure and requirements
Annex C (normative) - Plug and outlet interoperability
qualification
Annex D (normative) - General requirements for the
measurement set-up
Annex E (normative) - Insertion loss
Annex F (normative) - Return loss
Annex G (normative) - Near end cross talk (NEXT)
Annex H (normative) - Far end cross talk (FEXT)
Annex I (normative) - Transverse Conversion Loss
(TCL) and Transverse Conversion Transfer
Loss (TCTL)
Annex J (normative) - Termination of balun
Bibliography
IEC 61076-3-104:2017 establishes uniform specifications, type testing requirements for 8 way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz, and used as category 7A connectors in class FA cabling systems specified in ISO/IEC 11801-1. It contains all test methods and sequences, severity and preferred values for dimensions and characteristics.
This third edition of IEC 61076-3-104 cancels and replaces the second edition, published in 2006, and constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- the title has been changed to incorporate transmissions with frequencies up to 2 000 MHz;
- the drawings of some styles have been corrected for clarification;
- Figures 23 and 24 have been updated;
- Figure 3 has been updated to include reference dimensions and dimensional format changes;
- the dimensions of Figure 7 have been updated;
- the type designation and ordering information has been removed for consistency with the most updated sectional specification;
- the test schedule was updated to include appropriate IEC 60512 Test Nos;
- the electrical performance requirements have been revised for 2 GHz level and interchangeability information has been added for performance categories.
Committee |
TC 48/SC 48B
|
DevelopmentNote |
Supersedes IEC PAS 61076-3-104 (04/2003) Stability Date: 2019. (05/2017)
|
DocumentType |
Standard
|
ISBN |
978-2-8322-8534-3
|
Pages |
167
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN 61076-3-104:2006 | Identical |
EN 61076-3-104:2017 | Identical |
DIN EN 61076-3-104 : 2018 | Identical |
UNE-EN 61076-3-104:2017 | Identical |
BS EN 61076-3-104:2017 | Identical |
DIN EN 61076-3-104 : 2007 | Identical |
NEN EN IEC 61076-3-104 : 2017 | Identical |
CEI EN 61076-3-104 : 2007 | Identical |
PN EN 61076-3-104 : 2017 | Identical |
SN EN 61076-3-104 : 2003 | Identical |
NF EN 61076 3 104 : 2013 | Identical |
VDE 0687-76-3-104 : 2018 | Identical |
CEI EN 61935-2 : 2011 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 2: CORDS AS SPECIFIED IN ISO/IEC 11801 AND RELATED STANDARDS |
BS ISO/IEC 11801-1:2017 | Information technology. Generic cabling for customer premises General requirements |
I.S. EN 60512-25-9:2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
I.S. EN 50173-4:2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
CSA ISO/IEC 15018 : 2005 : R2010 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018:2005 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R201000 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CEI EN 61375-3-4 : 2014 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-4: ETHERNET CONSIST NETWORK (ECN) |
EN 61935-2:2010 | Specification for the testing of balanced and coaxial information technology cabling - Part 2: Cords as specified in ISO/IEC 11801 and related standards |
EN 60512-25-9 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
DEFSTAN 21-88(PT4)/4(2012) : 2012 | POLICIES AND PROCEDURES FOR SYSTEM INTEGRATION IN SURFACE SHIPS - PART 4: LEGACY PLATFORM DEDICATED INTERFACES |
DEFSTAN 21-88/2(2006) : 2006 | POLICIES AND PROCEDURES FOR COMBAT SYSTEM INTEGRATION IN SURFACE SHIPS (SSP 88) |
NF EN 61935-1 : 2010 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
16/30325955 DC : 0 | BS ISO/IEC 11801-5 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 5: DATA CENTRES |
PD ISO/IEC TR 29125:2010 | Information technology. Telecommunications cabling requirements for remote powering of terminal equipment |
CEI EN 61935-1 : 2010 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
CLC/TR 50173-99-3:2012 | Information technology - Generic cabling systems - Part 99-3: Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications |
CSA ISO/IEC 24740 : 2008 : R2013 | INFORMATION TECHNOLOGY - RESPONSIVE LINK (RL) |
I.S. EN 60512-28-100:2013 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 28-100: SIGNAL INTEGRITY TESTS UP TO 1000 MHZ ON IEC 60603-7 AND IEC 61076-3 SERIES CONNECTORS - TESTS 28A TO 28G (IEC 60512-28-100:2013(EQV)) |
EN 50173-5 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 5: DATA CENTRES |
I.S. EN 50173-2:2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 2: OFFICE PREMISES |
I.S. EN 61935-2:2010 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 2: CORDS AS SPECIFIED IN ISO/IEC 11801 AND RELATED STANDARDS |
ISO/IEC TR 29125:2010 | Information technology Telecommunications cabling requirements for remote powering of terminal equipment |
I.S. EN 50173-3:2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
EN 50173-4 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
NF EN 50173-4 : 2010 AMD 2 2013 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
IEC 61375-3-4:2014 | Electronic railway equipment - Train communication network (TCN) - Part 3-4: Ethernet Consist Network (ECN) |
CEI CLC/TR 50173-99-3 : 2013 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 99-3: HOME CABLING INFRASTRUCTURES UP TO 50 M IN LENGTH TO SUPPORT SIMULTANEOUS AND NON SIMULTANEOUS PROVISION OF APPLICATIONS |
16/30325974 DC : 0 | BS ISO/IEC 11801-2 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 2: OFFICE PREMISES |
BS EN 61375-3-4 : 2014 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-4: ETHERNET CONSIST NETWORK (ECN) (IEC 61375-3-4:2014) |
I.S. EN 50173-1:2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
ISO/IEC 14165-114:2005 | Information technology Fibre Channel Part 114: 100 MB/s Balanced copper physical interface (FC-100-DF-EL-S) |
CSA ISO/IEC 14165-114: 2006 | INFORMATION TECHNOLOGY - FIBRE CHANNEL - PART 114: 100 MB/S BALANCED COPPER PHYSICAL INTERFACE (FC-100-DF-EL-S) |
CEI EN 50173-1 : 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
S.R. CLC/TR 50173-99-3:2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 99-3: HOME CABLING INFRASTRUCTURES UP TO 50 M IN LENGTH TO SUPPORT SIMULTANEOUS AND NON SIMULTANEOUS PROVISION OF APPLICATIONS |
BS EN 50173-2 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 2: OFFICE PREMISES |
BS EN 50173-1:2011 | Information technology. Generic cabling systems General requirements |
NF EN 50173-1 : 2017 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
EN 60512-28-100:2013 | Connectors for electronic equipment - Tests and measurements - Part 28-100: Signal integrity tests up to 1 000 MHz on IEC 60603-7 and IEC 61076-3 series connectors - Tests 28a to 28g |
CEI EN 60512-25-9 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
EN 50173-3 : 2007 COR 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
CEI EN 60512-28-100 : 2014 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 28-100: SIGNAL INTEGRITY TESTS UP TO 1000 MHZ ON 60603-7 AND 61076-3 SERIES CONNECTORS - TESTS 28A TO 28G |
ISO/IEC TS 29125:2017 | Information technology Telecommunications cabling requirements for remote powering of terminal equipment |
PD CLC/TR 50173-99-3:2012 | Information technology. Generic cabling systems Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications |
16/30325971 DC : 0 | BS ISO/IEC 11801-1 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 1: GENERAL REQUIREMENTS |
ISO/IEC 11801-5:2017 | Information technology Generic cabling for customer premises Part 5: Data centres |
BS EN 61935-1:2009 | Specification for the testing of balanced and coaxial information technology cabling Installed balanced cabling as specified in the standards series EN 50173 |
CAN/CSA-ISO/IEC 14165-114:2006(R2016) | INFORMATION TECHNOLOGY - FIBRE CHANNEL - PART 114: 100 MB/S BALANCED COPPER PHYSICAL INTERFACE (FC-100-DF-EL-S) |
CSA ISO/IEC 24740 : 2008 | INFORMATION TECHNOLOGY - RESPONSIVE LINK (RL) |
I.S. EN 50173-5:2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 5: DATA CENTRES |
BS EN 61935-2:2010 | Specification for the testing of balanced and coaxial information technology cabling Cords as specified in ISO/IEC 11801 and related standards |
I.S. EN 61375-3-4:2014 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-4: ETHERNET CONSIST NETWORK (ECN) |
ISO/IEC 24740:2008 | Information technology Responsive Link (RL) |
IEC 61935-2:2010 | Specification for the testing of balanced and coaxial information technology cabling - Part 2: Cords as specified in ISO/IEC 11801 and related standards |
IEC 60512-25-9:2008 | Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk |
BS EN 60512-25-9:2008 | Connectors for electronic equipment. Tests and measurements Signal integrity tests. Test 25i. Alien crosstalk |
BS EN 60512-28-100:2013 | Connectors for electronic equipment. Tests and measurements Signal integrity tests up to 1000 MHz on IEC 60603-7 and IEC 61076-3 series connectors. Tests 28a to 28g |
BS EN 50173-5 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 5: DATA CENTRES |
BS ISO/IEC 11801-2:2017 | Information technology. Generic cabling for customer premises Office premises |
NF EN 60512-25-9 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
ISO/IEC 11801-1:2017 | Information technology — Generic cabling for customer premises — Part 1: General requirements |
IEC 61935-1:2015 | Specification for the testing of balanced and coaxial information technology cabling - Part 1: Installed balanced cabling as specified in ISO/IEC 11801 and related standards |
BS EN 50173-3 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
BS ISO/IEC 11801-5:2017 | Information technology. Generic cabling for customer premises Data centres |
ISO/IEC 11801-2:2017 | Information technology Generic cabling for customer premises Part 2: Office premises |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R2015 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
BS EN 50173-4 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
I.S. EN 61935-1:2009 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
EN 61375-3-4:2014/A11:2017 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-4: ETHERNET CONSIST NETWORK (ECN) |
EN 61935-1:2009 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60352-3:1993 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
IEC 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
IEC 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 61076-3:2008 | Connectors for electronic equipment - Product requirements - Part 3: Rectangular connectors - Sectional specification |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 62153-4-12:2009 | Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware - Absorbing clamp method |
IEC 60512-9-2:2011 | Connectors for electronic equipment - Tests and measurements - Part 9-2: Endurance tests - Test 9b: Electrical load and temperature |
IEC 61156-9:2016 | Multicore and symmetrical pair/quad cables for digital communications - Part 9: Cables for channels with transmission characteristics up to 2 GHz - Sectional specification |
IEC 61156-10:2016 | Multicore and symmetrical pair/quad cables for digital communications - Part 10: Cables for cords with transmission characteristics up to 2 GHz - Sectional specification |
IEC 60512-13-2:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-2: Mechanical operation tests - Test 13b: Insertion and withdrawal forces |
IEC 60512-2-5:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-5: Electrical continuity and contact resistance tests - Test 2e: Contact disturbance |
IEC 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
IEC 61156-2:2010 | Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification |
AS 11801.2:2019 | Information technology - Generic cabling for customer premises Office premises (ISO/IEC 11801-2:2017, MOD) |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
IEC 60512-9-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
IEC 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11-7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
IEC 61156-7:2003+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 7: Symmetrical pair cables with transmissioncharacteristics up to 1 200 MHz - Sectional specification fordigital and analog communication cables |
IEC 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
IEC 61156-6:2010+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 6: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Work area wiring -Sectional specification |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
IEC 61156-5:2009+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification |
IEC 61156-4:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification |
IEC 61156-3:2008 | Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification |
IEC 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
EN 50289-1-14:2004 | Communication cables - Specifications for test methods - Part 1-14: Electrical test methods - Coupling attenuation or screening attenuation of connecting hardware |
IEC 60512-15-6:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-6: Connector tests (mechanical) - Test 15f: Effectiveness of connector coupling devices |
IEC 60512-25-9:2008 | Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
IEC 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.