98/230636 DC : DRAFT MARCH 98

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

DRAFT IEC 61010-2-031 - SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT CONTROL AND LABORATORY USE 2-031: SAFETY REQUIREMENTS FOR HAND-HELD PROBE ASSEMBLIES FOR ELECTRICAL MEASUREMENT TEST

Published date

23-11-2012

Superseded date

15-03-2002

Superseded by

BS EN 61010-031:2015

Sorry this product is not available in your region.
Summarise this standard

1 Scope and object
   1.1 Scope
   1.2 Object
   1.3 Verification
   1.4 Environmental conditions
2 Normative references
3 Definitions
   3.1 Parts and accessories
   3.2 Electrical quantities
   3.3 Tests
   3.4 Safety terms
   3.5 Insulation
   3.6 Insulation co-ordination
   3.7 Mains
4 Tests
   4.1 General
   4.2 Sequence of tests
   4.3 Reference test conditions
   4.4 Testing in single fault condition
5 Marking and documentation
   5.1 Marking
   5.2 Warning markings
   5.3 Durability of marking
   5.4 Documentation
6 Protection against electric shock
   6.1 General
   6.2 Determination of ACCESSIBLE parts
   6.3 Permissible limits for ACCESSIBLE parts
   6.4 Insulation requirements for protection against
       electric shock
   6.5 Clearances and creepage distances
   6.6 Dielectric Strength tests
   6.7 Constructional requirements for protection against
       electric shock
7 Protection against mechanical hazards
8 Mechanical resistance to shock and impact
   8.1 Rigidity Test
   8.2 Drop Test
   8.3 Impact swing test
9 Temperature limits and protection against the spread of fire
   9.1 General
10 Resistance to heat
   10.1 Integrity of clearances and creepage distances
   10.2 Resistance to heat of probe assemblies
11 Protection against hazards from fluids
   11.1 General
   11.2 Cleaning
   11.3 Special protected probe assemblies
12 Protection against explosion
   12.1 Arc explosion
13 Components
   13.1 General
   13.2 Fuses
   13.3 High integrity components
Annexes
A (normative) Measuring circuits for ACCESSIBLE current (see 6.3)
B (normative) Standard test fingers (see 6.2)
C (normative) Measurement of CREEPAGE DISTANCES and CLEARANCES

Committee
EPL/66
DocumentType
Draft
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Sorry this product is not available in your region.