AAMI ISO 8637 : 2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

CARDIOVASCULAR IMPLANTS AND EXTRACORPOREAL SYSTEMS - HEMODIALYZERS, HEMODIAFILTERS, HEMOFILTERS AND HEMOCONCENTRATORS

Available format(s)

PDF

Language(s)

English

Published date

01-01-2010

Superseded date

02-09-2021

Superseded by

AAMI ISO 23500 : 2011

$292.92
Including GST where applicable

Glossary of equivalent standards
Committee representation
Background of ANSI/AAMI adoption of ISO 8637:2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
6 Labeling
Bibliography

Describes requirements for hemodialyzers, hemodiafilters, hemofilters and hemoconcentrators for use in humans.

Committee
WG 05
DevelopmentNote
Supersedes AAMI RD16. (02/2011)
DocumentType
Standard
ISBN
157020390-3
Pages
32
ProductNote
NEW CHILD AMD 1 2013 IS NOW ADDED.
PublisherName
Association for the Advancement of Medical Instrumentation
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
ISO 8637:2010 Identical

ISO 11137-1:2006 Sterilization of health care products — Radiation — Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
ISO 15223-2:2010 Medical devices — Symbols to be used with medical device labels, labelling, and information to be supplied — Part 2: Symbol development, selection and validation
ISO/TS 17665-2:2009 Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1
ISO 8638:2010 Cardiovascular implants and extracorporeal systems — Extracorporeal blood circuit for haemodialysers, haemodiafilters and haemofilters
ISO 14937:2009 Sterilization of health care products — General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
ISO 11135-1:2007 Sterilization of health care products — Ethylene oxide — Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
ISO 11137-3:2017 Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control
ISO 10993-7:2008 Biological evaluation of medical devices — Part 7: Ethylene oxide sterilization residuals
ISO 11137-2:2013 Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose
ISO 10993-1:2009 Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process
ISO/TS 11135-2:2008 Sterilization of health care products — Ethylene oxide — Part 2: Guidance on the application of ISO 11135-1
ISO 7000:2014 Graphical symbols for use on equipment — Registered symbols
ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment — Part 2: Lock fittings
ISO 15223-1:2016 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied — Part 1: General requirements
ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

$292.92
Including GST where applicable