Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 1023.2-1989

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Low voltage switchgear and controlgear - Protection of electric motors - Current sensing protection devices for a.c. motors

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1989

Superseded date

29-05-2024

Superseded by

AS 3947.4.1-1995

$114.35
Including GST where applicable
Summarise this standard

Specifies requirements for five types of device or relay to protect a.c. electric motors from overtemperature damage caused by overload, phase failure or stalled drive, by sensing the magnitude, duration and, depending on the type, other properties of motor currents.

Committee
EL-006
DocumentType
Standard
ISBN
0 7262 5252 2
Pages
40
ProductNote
To run concurrently with AS 3947.4.1-1995
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard applies to current-sensing devices or relays as classified in Clause 1.5 according to their function(s) for the protection of a.c. electric motors.NOTE:1. When used in motor starters, these devices are also required to comply with the relevant requirements of the AS 1202 series of Standards.2. In this Standard the term motor protection relay has a different meaning to that in the previous edition, see Clause 1.4.2.This Standard covers requirements for protection of the motor against-overload; phase failure; and stalled drive.NOTE: A specific device complying with this Standard may not provide phase failure or stalled drive protection.In addition, such devices may provide the following features which are outside the scope of this Standard: (a) Remote temperature sensing input(s).(b) Protection of the motor against other conditions such as-earth fault; phase current imbalance; phase-sequence reversal; and short-circuit.NOTE: Such short-circuit protection is distinct from protection of circuit wiring afforded by circuit-breakers or fuses.This Standard does not apply to the following types of motor overload protection device: (i) Devices operated wholly by the temperature of the frame or windings of a motor.(ii) Devices operated partly by the temperature of the frame or windings of the motor, as covered by AS 1023.3.(iii) Thermally operated, self-resetting devices of the type used in refrigerating units.(iv) Devices built into motor-operated appliances.

⚠

A newer version of this standard is available.

View Current Edition
$114.35
Including GST where applicable