Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 1026-1992

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electric cables - Impregnated paper insulated - Working voltages up to and including 33 kV

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

01-01-1992

Superseded date

22-05-2024

Superseded by

AS/NZS 1026:2004

$130.14
Including GST where applicable
Summarise this standard

1 - AS 1026-1992 ELECTRIC CABLES - IMPREGNATED PAPER INSULATED - WORKING VOLTAGES UP TO AND INCLUDING 33 kV
4 - PREFACE
5 - CONTENTS
7 - 1 SCOPE
7 - 2 REFERENCED DOCUMENTS
7 - 3 DEFINITIONS
7 - 3.1 Core (of a cable)
7 - 3.2 Conductor screen
7 - 3.3 Screened cable
8 - 3.4 Multicore cable
8 - 3.5 Belted cable
8 - 3.6 Separately leaded (SL) cable
8 - 3.7 Direction of lay
8 - 3.8 Maximum permissible continuous conductor temperature
8 - 3.9 Voltage designation
8 - 3.10 Nominal values
8 - 3.11 Approximate value
8 - 3.12 Breaking joint
8 - 3.13 Registration
8 - 3.14 Non-hygroscopic
8 - 4 OPERATING VOLTAGES
8 - 5 MAXIMUM CONDUCTOR TEMPERATURES
8 - 6 CONDUCTORS
10 - 7 CONDUCTOR SCREEN
10 - 8 INSULATION
10 - 8.1 General
10 - 8.2 Material
10 - 8.3 Method of application
10 - 8.4 Thickness of paper
10 - 8.5 Thickness of insulation
10 - 9 CORE IDENTIFICATION
10 - 10 INSULATION SCREEN
10 - 10.1 General
10 - 10.2 Screen
10 - 10.3 Additional screening
10 - 11 LAYING UP
10 - 11.1 Belted cables
11 - 11.2 Screened cables
11 - 11.3 Screened SL cables
11 - 11.4 Direction of lay
11 - 12 IMPREGNATION
11 - 12.1 General
11 - 12.2 Compound test
11 - 12.3 Breaking load and elongation at break of impregnated paper
11 - 13 IDENTIFICATION OF MANUFACTURER
11 - 14 LEAD ALLOY SHEATH
11 - 14.1 General
11 - 14.2 Composition
11 - 14.3 Thickness
11 - 14.4 External coating
11 - 15 BEDDING
11 - 15.1 General
11 - 15.2 Lapped bedding
11 - 15.3 Extruded bedding
12 - 16 ARMOUR
12 - 16.1 General
12 - 16.2 Single-wire armour
12 - 16.3 Double-wire armour
12 - 17 NON-METALLIC SHEATH OR SERVING
12 - 17.1 Non-metallic sheath
12 - 17.2 Serving for armoured cables
12 - 18 COMPOUNDS FOR LAPPED BEDDING AND SERVING
12 - 19 CABLE MARKINGS
12 - 19.1 End markings
12 - 19.2 Identification of cables without non-metallic sheath
13 - 19.3 Embossing or indenting of non-metallic sheath
13 - 19.4 Metre marking on non-metallic sheath
13 - 20 SEALING AND PREPARATION FOR DELIVERY
13 - 20.1 General
13 - 21 TESTS
13 - 21.1 General
13 - 21.2 Test categories
13 - 21.3 Measurement of conductor resistance (RT)
13 - 21.4 Voltage tests (RT)
14 - 21.5 Dielectric dissipation factor/voltage test (RT)
15 - 21.6 Electrical tests on extruded non-metallic sheaths (RT)
15 - 21.7 Measurement of insulation thickness (ST)
16 - 21.8 Bending test (ST)
16 - 21.9 Drainage test (ST)
17 - 21.10 Residual compound congealing point test
17 - 21.11 Breaking load and elongation at break of impregnated paper (ST)
28 - APPENDIX A - RECOMMENDATIONS FOR THE SELECTION AND OPERATION OF PAPER-INSULATED CABLES
28 - A1 VOLTAGE RATINGS
28 - A1.1 Categories
28 - A1.2 Category 1
28 - A1.3 Category 2
28 - A2 PROTECTIVE COVERINGS
28 - A2.1 Non-metallic sheath
28 - A2.2 Flame-retardant coverings
28 - A3 PROTECTION AGAINST TERMITE OR ANT ATTACK
28 - A4 CURRENT RATINGS
28 - A5 SHORT CIRCUIT RATINGS
30 - APPENDIX B - RECOMMENDATIONS FOR THE INSTALLATION OF PAPER-INSULATED CABLES
30 - B1 MINIMUM TEMPERATURE DURING INSTALLATION
30 - B2 MINIMUM INSTALLATION RADIUS
30 - B3 TESTS AFTER INSTALLATION
32 - APPENDIX C - SPECIAL TEST SAMPLE SELECTION AND RETEST PROCEDURE
32 - C1 SELECTION OF SAMPLES
32 - C2 RE-TEST PROCEDURE
33 - APPENDIX D - TYPE TESTS FOR 19/33 kV CABLES
33 - D1 PRELIMINARY PROCEDURE
33 - D2 LOADING CYCLE TEST
33 - D2.1 Test installation
33 - D2.2 PROCEDURE
33 - D3 IMPULSE VOLTAGE TEST
33 - D3.1 Test installation
33 - D3.2 Principle
33 - D3.3 Detailed test method
35 - APPENDIX E - METHOD OF TEST FOR WATER-SOLUBLE IMPURITIES IN INSULATING PAPER
35 - APPENDIX F - INFORMATION REQUIRED WITH ENQUIRY AND ORDER
36 - APPENDIX G - DETERMINATION OF THICKNESS OF LEAD ALLOY SHEATH AND EXTRUDED BEDDING
36 - G1 GENERAL
36 - G2 METHOD OF MEASURING THICKNESS
36 - G2.1 Lead alloy sheath
36 - G2.2 Extruded bedding

Specifies the requirements for non-draining mass-impregnated paper insulated and lead alloy sheathed cables for working voltages up to and including 19/33 kV.

Committee
EL-003
DocumentType
Standard
ISBN
0 7262 7678 2
Pages
31
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for non-draining mass-impregnated paper insulated and lead alloy sheathed cables for working voltages up to and including 19/33 kV. Provision is made for extruded or lapped non-metallic protective coverings over the lead alloy sheath, with or without galvanized steel wire armour. Some typical constructions are shown in Figure 1.NOTE: Recommendations for selection and operation are given in Appendix A and those for installation are given in Appendix B.The following cables are included in this Standard:(a) 0.6/1 kV single-core, two-core, three-core and four-core.(b) 1.9/3.3 kV and 3.8/6.6 kV single-core and three-core belted construction.(c) 6.35/11 and 11/11 kV single-core and three-core belted or screened construction.(d) 12.7/22 kV and 19/33 kV single-core and three-core screened or three-core separately leaded (SL).

First published as AS C92-1941.
Withdrawn 1970.
Revised and redesignated AS 1026-1973.
Second edition 1992.

⚠

A newer version of this standard is available.

View Current Edition
$130.14
Including GST where applicable