Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 1259.2-1990

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Acoustics - Sound level meters Integrating - Averaging

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1990

Superseded date

24-06-2021

$160.49
Including GST where applicable
Summarise this standard

1 - AS 1259.2-1990 ACOUSTICS - SOUND LEVEL METERS - INTEGRATING - AVERAGING
4 - PREFACE
5 - CONTENTS
6 - 1. Scope
6 - 1.1 General
6 - 1.2 Types
6 - 1.3 Characteristics specified
7 - 1.4 Tolerances
7 - 1.5 Tests specified
7 - 2. Object and general requirements
7 - 2.1 Object
7 - 2.2 Applications
8 - 2.3 General requirements
8 - 2.4 Method of use
8 - 3. Definitions
11 - 4. General characteristics
12 - 5. Frequency weighting and amplifier characteristics
12 - 6. Averaging and indicator characteristics
14 - 7. Overload indication
14 - 8. Sensitivity to various environments
15 - 9. Calibration and verification of the basic characteristics
15 - 9.1 Introduction
15 - 9.2 Overall instrument characteristics
16 - 9.3 Amplifier and indicator characteristics
19 - 10. Provision for use with auxiliary equipment
19 - 11. Rating information and instruction manual
22 - APPENDIX A* - DIFFERENCE BETWEEN AVERAGING CAPABILITY OF INTEGRATING AND CONVENTIONAL SOUND LEVEL METERS
23 - APPENDIX B* - ADDITIONAL SPECIFICATIONS FOR INTEGRATING SOUND LEVEL METERS INDICATING THE AVERAGE A1-WEIGHTED SOUND PRESSURE
23 - B1. Definition
23 - B2. Characteristics
24 - B3. Test
25 - APPENDIX C* - USE OF FREE FIELD AND DIFFUSE FIELD MICROPHONES
26 - APPENDIX D* - TESTING THE RESPONSE OF AN INTEGRATING SOUND LEVEL METER TO ONE-CYCLE TONE BURSTS

Describes instruments for the measurement of frequency weighted and time averaged sound pressure levels. Optionally, sound exposure levels may be measured. Specifies additional characteristics to those in AS 1259.1 which are necessary to measure the equivalent continuous sound pressure level (Leq) of steady, intermittent, fluctuating and impulsive sounds. Identical with and reproduced from IEC 804.

Committee
AV-002
DocumentType
Standard
ISBN
0 7262 6153 X
Pages
22
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This standard describes instruments for the measurement of frequency weighted and time averaged sound pressure levels. Optionally, sound exposure levels may be measured. This standard is consistent with the relevant requirements of IEC Publication 651: Sound Level Meters, but specifies additional characteristics which are necessary to measure the equivalent continuous sound pressure level, Leq, of steady, intermittent, fluctuating and impulsive sounds.Note. - Standardization of an instrument for the measurement of the equivalent continuous sound pressure level and optionally the sound exposure level does not imply that these quantities completely characterize the psychological and physiological effects of sound on man.Though a complete integrating sound level meter is specified, the combination of a conventional sound level meter that satisfies IEC Publication 651 and an accessory or "plug-in" that provides the averaging capability is admissible if the complete system satisfies this standard.The instrument is called "integrating-averaging sound level meter", but the short form "integrating sound level meter" or "averaging sound level meter" may also be used. In this standard, "integrating sound level meter" is used.There are some important differences between the time averaging characteristics of an integrating sound level meter and those of a conventional sound level meter. These differences are discussed in Appendix A.This standard specifies integrating sound level meters of four degrees of accuracy, designated Types 0,1, 2 and 3.For each type, the specification for directional characteristics and frequency weighting and amplifier characteristics are identical to those of IEC Publication 651. Averaging and indicator specifications differ from IEC Publication 651 and it should be noted that they are identical for Types 2 and 3 instruments.The mark "R" on the instrument, if any, indicates that this instrument is calibrated for diffuse field (see Sub-clauses 2.3.3 and 9.1).This standard specifies the following characteristics and test methods for integrating sound level meters: a) integrating and averaging characteristics; b) indicator characteristics; c) overload sensing and indicating characteristics.Integrating sound level meters shall also comply with the requirements in IEC Publication 651 as follows:a) directional characteristics b) frequency weighting characteristics c) sensitivity to various environmentsThe specifications for Types 0, 1, 2 and 3 integrating sound level meters have the same centre values and differ only in the tolerances allowed. Tolerances broaden as the type number increases.This standard specifies electrical and acoustical tests to verify compliance with the characteristics specified (see Sub-clause 1.3).

Standards Relationship
IEC 60804:1985 Identical
IEC 60804:2000 Identical

⚠

A newer version of this standard is available.

View Current Edition View Current Edition
$160.49
Including GST where applicable