AS 1670.2-1997

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire detection, warning, control and intercom systems - System design, installation and commissioning - Local fire

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1997

Superseded date

25-07-2024

Superseded by

AS 1670.1-2004

$114.35
Including GST where applicable
Summarise this standard

1 - AS 1670.2-1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM SYSTEMS-SYSTEM DESIGN, INSTALLATION AND COMMISSIONING - LOCAL FIRE
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 REFERENCED AND RELATED DOCUMENTS
6 - 1.4 DEFINITIONS
6 - 1.4.1 Egress path
6 - 1.4.2 Extra low voltage (ELV)
6 - 1.4.3 Habitable room
6 - 1.4.4 Level surface
6 - 1.4.5 Local fire indicator panel (LFIP)
6 - 1.4.6 Low voltage (LV)
6 - 1.4.7 Multi-station smoke alarms
6 - 1.4.8 Power supply
6 - 1.4.9 Protected area
7 - 1.5 COMPLIANCE WITH OTHER STANDARDS
7 - 1.6 INTERPRETATION OF SPECIFIED LIMITING VALUES
8 - SECTION 2 GENERAL REQUIREMENTS
8 - 2.1 COMPONENTS
8 - 2.2 SEPARATION OF SYSTEMS
9 - SECTION 3 TYPES OF LOCAL FIRE ALARM SYSTEMS
9 - 3.1 SYSTEM TYPES
9 - 3.1.1 General
9 - 3.1.2 Type 1
9 - 3.1.3 Type 2
9 - 3.1.4 Type 3
9 - 3.1.5 Type 4
9 - 3.2 ALARM ZONE LIMITATIONS
9 - 3.2.1 General
9 - 3.2.2 Number of actuating devices
9 - 3.2.3 Concealed spaces
11 - SECTION 4 INSTALLATION REQUIREMENTS
11 - 4.1 GENERAL
11 - 4.2 POWER SOURCE
11 - 4.2.1 Power source (primary)
11 - 4.2.2 Power source (secondary)
11 - 4.3 SEPARATION OF WIRING SYSTEMS
11 - 4.4 CONNECTION TO EXISTING INSTALLATIONS
11 - 4.5 EQUIPMENT AND ITS LOCATION
11 - 4.5.1 General
11 - 4.5.2 Local fire indicator panel
12 - 4.5.3 Detectors
12 - 4.6 WARNING SYSTEMS
12 - 4.7 ANCILLARY LOADS
12 - 4.8 AIRCONDITIONING AND MECHANICAL VENTILATION
12 - 4.9 SUPERVISION
12 - 4.10 INSTALLATION WIRING
12 - 4.10.1 General
13 - 4.10.2 Conductors
13 - 4.10.3 Cable colours
13 - 4.10.4 Joints and terminations
14 - SECTION 5 COMMISSIONING OF INSTALLATION
14 - 5.1 GENERAL
14 - 5.2 COMMISSIONING TESTS
15 - 5.3 STATEMENT OF COMPLIANCE
15 - 5.4 LOG
15 - 5.5 LFIP DOCUMENTATION
17 - APPENDIX A - LIST OF REFERENCED AND RELATED DOCUMENTS
17 - REFERENCED DOCUMENTS
17 - RELATED DOCUMENTS
18 - APPENDIX B - TYPICAL COMMISSIONING TEST REPORT
20 - APPENDIX C - STANDARD FORM OF STATEMENT OF COMPLIANCE FOR LOCAL FIRE ALARM SYSTEMS

Specifies requirements for the design, installation and commissioning of local alarm systems used for early warning fire detection and life safety in situations where there is no legislative requirement for a system, no monitoring station connection requirement, or no monitoring facility available.

Committee
FP-002
DocumentType
Standard
ISBN
0 7337 1604 0
Pages
16
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard sets out the requirements for the system design, installation and commissioning of local fire detection and alarm systems (i.e. not requiring connection to a monitoring service) and components that are manufactured in accordance with the AS 1603 suite of Standards and AS 3786, and fire indicator panels complying with AS 4428.1.These systems are concerned with early warning fire detection and life safety of persons occupying a single building only and do not provide for the connection of subindicator panels.

First published as AS 1670.2-1997.

⚠

A newer version of this standard is available.

View Current Edition
$114.35
Including GST where applicable