Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 1807.6-2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of integrity of terminally mounted HEPA filter installations

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

15-02-2000

Superseded date

25-07-2024

Superseded by

AS 1807:2021

$38.24
Including GST where applicable

1 - AS 1807.6-2000 CLEANROOMS, WORKSTATIONS, SAFETY CABINETS AND PHARMACEUTICAL ISOLATORS-METHODS OF TEST - DETERMINATION OF INTE
1 - 1 SCOPE
1 - 2 REFERENCED DOCUMENTS
1 - 3 DEFINITIONS
2 - 4 PRINCIPLE
2 - 5 AEROSOL TEST LIQUID
2 - 6 APPARATUS
2 - 7 PROCEDURE
3 - 8 REPORT
4 - AMENDMENT CONTROL SHEET

This Standard sets out the method for determining the overall integrity of a terminally mounted HEPA filter installation in a cleanroom, workstation, safety cabinet, or pharmaceutical isolator.

Committee
ME-060
DocumentType
Standard
ISBN
0 7337 3219 4
Pages
3
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard sets out the method for determining the overall integrity of a terminally mounted HEPA filter installation in a cleanroom, workstation, safety cabinet, or pharmaceutical isolator.NOTE: A test method for determination of the overall integrity of HEPA filter installations which are not terminally mounted is specified in AS 1807.7.

First published as AS 1807.6-1976.
Second edition 1989.
Third edition 2000.

AS 4260-1997 High efficiency particulate air (HEPA) filters - Classification, construction and performance (Reconfirmed 2018)
AS 1807.0-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test List of methods and apparatus
AS 1807.3-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air velocity in laminar flow cleanrooms
AS 1807.1-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air velocity and uniformity of air velocity in clean workstations, laminar flow safety cabinets and pharmaceutical isolators
AS 1807.7-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of integrity of HEPA filter installations not terminally mounted
AS/NZS 1716:2003 Respiratory protective devices
AS 1386.1-1989 Cleanrooms and clean workstations - Principles of clean space control

AS/NZS 2243.3:2002 Safety in laboratories Microbiological aspects and containment facilities
AS 2252.1-2002 Biological safety cabinets Biological safety cabinets (Class I) for personnel and environment protection
AS 2252.2-2004 Biological safety cabinets - Laminar flow biological safety cabinets (Class II) for personnel, environment and product protection
AS 1807.7-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of integrity of HEPA filter installations not terminally mounted
AS 2567-2002 Laminar flow cytotoxic drug safety cabinets
AS 2252.6-2011 Controlled environments Clean workstations - Design, installation and use
AS 2252.2-2009 Controlled environments Biological safety cabinets Class II - Design
HB 260-2003 Hospital acquired infections - Engineering down the risk
AS 1386.5-1989 Cleanrooms and clean workstations - Clean workstations
AS/NZS 2243.3:2010 Safety in laboratories Microbiological safety and containment
AS 1807.5-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of work zone integrity
AS 2252.5:2017 Controlled environments Cytotoxic drug safety cabinets (CDSC) - Design, construction, installation, testing and use
AS 1324.2-2003 Air filters for use in general ventilation and airconditioning Methods of test
AS 1386.7-1989 Cleanrooms and clean workstations - Installation and use of clean workstations
AS 1807.22-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of air barrier containment of laminar flow safety cabinets
AS 1386.3-1989 Cleanrooms and clean workstations - Non-laminar flow cleanrooms - Class 350 and cleaner
AS 1386.2-1989 Cleanrooms and clean workstations - Laminar flow cleanrooms

$38.24
Including GST where applicable