AS 2118.4-1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Automatic fire sprinkler systems - Residential

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1995

Superseded date

25-06-2021

Superseded by

AS 2118.4-2012

$49.72
Including GST where applicable
Summarise this standard

1 - AS 2118.4-1995 AUTOMATIC FIRE SPRINKLER SYSTEMS - RESIDENTIAL
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 NEW DESIGNS AND INNOVATIONS
6 - 1.3 REFERENCED DOCUMENTS
6 - 1.4 DEFINITIONS
7 - 1.4.1 Compartment
7 - 1.4.2 Design discharge
7 - 1.4.3 Listed
7 - 1.4.4 Residential sprinkler
7 - 1.4.5 Sole occupancy unit
7 - 1.5 APPLICATION
8 - SECTION 2 DESIGN AND INSTALLATION REQUIREMENTS
8 - 2.1 GENERAL
8 - 2.2 WORKING DRAWINGS
8 - 2.2.1 General
8 - 2.2.2 Approval requirements
9 - 2.2.3 Acceptance tests
9 - 2.2.4 Compliance requirements
9 - 2.3 WATER SUPPLY
9 - 2.3.1 General
9 - 2.3.2 Connection to town main
10 - 2.3.3 Connection to private water supplies
10 - 2.3.4 Connection to fire hose reels
10 - 2.3.5 Pumpset
10 - 2.4 DESIGN CRITERIA INSIDE THE RESIDENTIAL OCCUPANCY
10 - 2.4.1 Design discharge
10 - 2.4.2 Design number of sprinklers
10 - 2.4.3 Water pressure/flow requirements
11 - 2.5 DESIGN CRITERIA OUTSIDE THE RESIDENTIAL OCCUPANCY
11 - 2.6 SPRINKLERS
11 - 2.6.1 Types of sprinklers
11 - 2.6.2 Normal temperature ratings
11 - 2.6.3 High temperature ratings
11 - 2.6.4 Compatibility
11 - 2.6.5 Positioning of sprinklers
11 - 2.6.6 Positioning of sprinklers under skylights
11 - 2.7 SYSTEM TYPES
11 - 2.7.1 Wet systems
11 - 2.7.2 Systems subject to freezing
11 - 2.8 PIPE SIZING
12 - 2.9 PIPING LAYOUTS
12 - 2.10 EXTENT OF SPRINKLER PROTECTION
12 - 2.10.1 General
12 - 2.11 AREA OF COVERAGE
12 - 2.12 ELECTRICAL WIRING
13 - SECTION 3 MARKING AND IDENTIFICATION
13 - 3.1 IDENTIFICATION
13 - 3.2 SITE PLAN
13 - 3.3 STOCK OF REPLACEMENT SPRINKLERS
13 - 3.4 OPERATING INSTRUCTIONS
14 - SECTION 4 COMPONENTS
14 - 4.1 GENERAL
14 - 4.2 VALVE AND DRAINS
14 - 4.3 FIRE BRIGADE BOOSTER CONNECTION
14 - 4.4 PRESSURE GAUGES
14 - 4.5 PIPING
14 - 4.6 PIPING SUPPORT
14 - 4.7 SPRINKLERS
14 - 4.8 PAINTING AND ORNAMENTAL FINISHES
14 - 4.9 ALARMS
15 - 4.10 TRANSMISSION OF ALARM SIGNAL TO FIRE SERVICE
16 - APPENDIX A - RECOMMENDED SMOKE DETECTOR REQUIREMENTS
17 - APPENDIX B - COMPLETION CERTIFICATE
18 - APPENDIX C - MAINTENANCE

Specifies the design, installation and commissioning of sprinklers for life safety and property protection for the inhabitants of low-rise Class 2 and Class 3 buildings as defined in the BCA. In addition to providing an increased level of protection to building occupants, This Standard also considers the economic aspects of the sprinkler system. The purpose of this Standard is to provide design and installation requirements for a life safety sprinkler system in addition to smoke alarms, to aid in the detection and control of fires in residential occupancies and thus provide improved protection against injury and loss of life. A sprinkler system designed and installed in accordance with this Standard is expected to prevent flashover (total involvement) in the room of fire origin and to improve the chance for occupants to escape or be evacuated.

Committee
FP-004
DocumentType
Standard
ISBN
0 7262 9687 2
Pages
13
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for the design, installation and performance of automatic life safety fire sprinkler systems in residential buildings containing not more than four storeys.

First published as AS 2118.4-1995.

⚠

A newer version of this standard is available.

View Current Edition
$49.72
Including GST where applicable