AS 2118.6-1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Automatic fire sprinkler systems - Combined sprinkler and hydrant

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1995

Superseded date

11-07-2024

Superseded by

AS 2118.6-2012

$65.52
Including GST where applicable
Summarise this standard

1 - AS 2118.6-1995 AUTOMATIC FIRE SPRINKLER SYSTEMS - COMBINED SPRINKLER AND HYDRANT
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 NEW DESIGNS AND INNOVATIONS
6 - 1.3 REFERENCED DOCUMENTS
6 - 1.4 DEFINITIONS
6 - 1.4.1 Combined system
7 - SECTION 2 SYSTEM REQUIREMENTS
7 - 2.1 GENERAL
7 - 2.2 LOCATION AND ACCESS TO SPRINKLER CONTROL ASSEMBLIES
7 - 2.3 LOCATION AND ACCESS TO FIRE MAIN ISOLATION VALVES
7 - 2.4 ACCESS TO FIRE HYDRANTS
7 - 2.5 PROTECTION OF SUPPLY PIPING
7 - 2.6 FIRE MAIN (RING) RETICULATION
7 - 2.6.1 Pipe sizing
7 - 2.6.2 Pressure zones
8 - 2.6.3 Isolation valves
8 - 2.7 PRESSURE REDUCING VALVES
8 - 2.8 WATER SUPPLIES
8 - 2.8.1 Combined system water flow rate
8 - 2.8.2 Source of water supply
8 - 2.8.3 Fire mains (feed)
8 - 2.9 FIRE SERVICE BOOSTER
8 - 2.10 FIRE ALARM INITIATION
8 - 2.11 FIRE ALARM CIRCUITS
9 - 2.12 MONITORING OF ISOLATING VALVES
10 - SECTION 3 PIPES, VALVES AND FITTINGS
10 - 3.1 GENERAL
10 - 3.2 VALVES
10 - SECTION 4 TESTING
10 - 4.1 GENERAL
10 - 4.2 PRE-TEST PREPARATION
10 - 4.3 HYDROSTATIC TEST
10 - 4.4 FLOW TESTS
10 - 4.5 RECORDING OF TEST RESULTS
11 - APPENDIX A - REFERENCED DOCUMENTS
12 - APPENDIX B - LOCATION OF FIRE HYDRANTS AND SPRINKLER CONTROL VALVES
15 - APPENDIX C - SYSTEM PHILOSOPHY
20 - APPENDIX D - SYSTEM RESISTANCE CURVE FOR COMBINED SPRINKLER AND HYDRANT SYSTEMS
20 - D1 SCOPE
20 - D2 SYSTEM RESISTANCE CURVE EQUATIONS
22 - APPENDIX E - WIRING SYSTEMS RATING
22 - E1 PROTECTION AGAINST EXPOSURE TO FIRE
22 - E2 PROTECTION AGAINST MECHANICAL DAMAGE
23 - E3 PROTECTION AGAINST HOSING WITH WATER
24 - APPENDIX F - TYPICAL SPRINKLER CONTROL ASSEMBLIES AND PRESSURE CONTROL STATIONS

Specifies minimum requirements for the installation, commissioning and testing of combined sprinkler and hydrant systems for installation in multi-storey buildings as an alternative to the installation of separate sprinkler and hydrant systems.

Committee
FP-004
DocumentType
Standard
ISBN
0 7262 9753 4
Pages
20
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out the minimum requirements for the installation, commissioning and testing of a combined sprinkler and hydrant system, for installation in multistorey buildings as an alternative option to using separate sprinkler and hydrant systems, or separate sprinkler and hydrant installations utilizing a combined fire main (see AS 2118.1).

First published as AS 2118.6-1995.

⚠

A newer version of this standard is available.

View Current Edition
$65.52
Including GST where applicable