Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 2380.9-1991

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical equipment for explosive atmospheres - Explosion-protection techniques Type of protection n - Non-sparking

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

10-06-1991

Superseded date

29-05-2024

Superseded by

AS/NZS 60079.15:2006

$118.42
Including GST where applicable
Summarise this standard

1 - AS 2380.9-1991 ELECTRICAL EQUIPMENT FOR EXPLOSIVE ATMOSPHERES - EXPLOSION-PROTECTION TECHNIQUES - TYPE OF PROTECTION n - NON-
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 REFERENCED DOCUMENTS
6 - 1.3 DEFINITIONS
6 - 1.3.1 Type of protection ‘n’
6 - 1.3.2 Normal operation
7 - 1.3.3 Restricted-breathing enclosure
7 - 1.3.4 Enclosed-break device
7 - 1.3.5 Non-incendive component
7 - 1.3.6 Hermetically-sealed device
7 - 1.3.7 Sealed device
7 - 1.3.8 Energy-limited equipment and circuits
7 - 1.3.9 Separation
7 - 1.4 GROUPING OF EQUIPMENT
7 - 1.5 MARKING
8 - SECTION 2 REQUIREMENTS FOR THE CONSTRUCTION OF ALL ELECTRICAL EQUIPMENT
8 - 2.1 SCOPE OF SECTION
8 - 2.2 POTENTIAL IGNITION SOURCES
8 - 2.3 ENCLOSURES
8 - 2.3.1 General
8 - 2.3.2 Degree of protection
8 - 2.4 CONNECTION FACILITIES
8 - 2.4.1 General
8 - 2.4.2 Connections for external conductors
9 - 2.4.3 Internal connections and wiring
9 - 2.5 CLEARANCES, SEPARATIONS AND CREEPAGE DISTANCES
9 - 2.6 WINDINGS
10 - SECTION 3 SUPPLEMENTARY REQUIREMENTS FOR NON-SPARKING EQUIPMENT
10 - 3.1 ROTATING MACHINES
10 - 3.1.1 Temperature class
10 - 3.1.2 Bars
10 - 3.1.3 Clearance for fans
10 - 3.1.4 Earth terminal
10 - 3.1.5 Degree of protection of terminal boxes
10 - 3.1.6 Operation with a non-sinusoidal supply
10 - 3.2 FUSES AND FUSE ASSEMBLIES
10 - 3.2.1 Fuse requirements
10 - 3.2.2 Fuse temperature
10 - 3.3 PLUGS AND SOCKET-OUTLETS AND SIMILAR CONNECTORS
10 - 3.3.1 Mechanical requirements for internal connections
10 - 3.3.2 Identification of internal connections
10 - 3.3.3 External connections
10 - 3.3.4 General purpose socket-outlets
11 - 3.4 LUMINAIRES DESIGNED FOR MAINS SUPPLY
11 - 3.4.1 Temperature class
11 - 3.4.2 Enclosure
11 - 3.4.3 Connections
11 - 3.4.4 Bayonet lampholder design
11 - 3.4.5 Screw lampholder design
11 - 3.4.6 Bi-pin lampholders for tubular fluorescent lamps
11 - 3.4.7 Compliance with other Standards
11 - 3.4.8 Starters for fluorescent lamps
11 - 3.4.9 Starter holders
11 - 3.5 INSTRUMENTS AND LOW POWER EQUIPMENT
12 - SECTION 4 SUPPLEMENTARY REQUIREMENTS FOR EQUIPMENT PRODUCING OPERATIONAL ARCS, SPARKS OR HOT SURFACES
12 - 4.1 GENERAL
12 - 4.2 ENCLOSED-BREAK DEVICES AND NON-INCENDIVE COMPONENTS
12 - 4.2.1 Rating
12 - 4.2.2 Construction
12 - 4.3 HERMETICALLY-SEALED DEVICES
12 - 4.4 SEALED DEVICES
12 - 4.4.1 Construction
12 - 4.4.2 Gasket seals
12 - 4.4.3 Poured seals
12 - 4.4.4 Damage to seals
12 - 4.5 ENERGY-LIMITED EQUIPMENT AND CIRCUITS
13 - 4.6 RESTRICTED-BREATHING ENCLOSURES
13 - 4.6.1 General
13 - 4.6.2 Constructional requirements
14 - SECTION 5 VERIFICATION AND TESTS
14 - 5.1 TYPE VERIFICATION AND TESTS
14 - 5.2 DIELECTRIC STRENGTH TEST
14 - 5.3 TESTS FOR ENCLOSED-BREAK DEVICES AND NON-INCENDIVE COMPONENTS
14 - 5.3.1 Preparation of sample prior to type test
14 - 5.3.2 Tests
14 - 5.4 TEST FOR SEALED DEVICES
15 - 5.5 TEST FOR ENERGY-LIMITED EQUIPMENT AND CIRCUITS
15 - 5.5.1 General
15 - 5.5.2 Maximum voltage and current levels
15 - 5.5.3 Spark-test apparatus
15 - 5.5.4 Procedure
15 - 5.6 TESTS FOR RESTRICTED-BREATHING ENCLOSURES
15 - 5.6.1 General
15 - 5.6.2 Diffusion half-time test
16 - 5.6.3 Pressure half-time test
16 - 5.6.4 Air flow test
16 - 5.7 GASKET AND SEAL TEST
17 - APPENDIX A - RESTRICTED-BREATHING ENCLOSURES
17 - A1 RESTRICTED-BREATHING CONCEPT
17 - A2 PRINCIPLES OF THE CONCEPT
17 - A3 EXPLANATION OF TERMS
17 - A4 THEORY AND TEST REQUIREMENTS
18 - A5 CALCULATION OF TEST PARAMETERS

Specifies design, construction and testing requirements for non-sparking electrical equipment for use in explosive atmospheres. Includes the requirements for enclosed-break devices and non-incendive components, sealed devices and restricted-breathing enclosures. Technically similar to IEC 79-15.

Committee
EL-014
DocumentType
Standard
ISBN
0 7262 6909 3
Pages
16
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for the design, construction and testing of non-sparking type electrical equipment, intended for use in Class 1 Zone 2 hazardous areas.This Standard supplements AS 2380.1, except for the requirements of the following clauses which do not apply:2.1.4 Enclosed equipment2.2 Enclosures of non-metallic material2.3.2 Group II equipment2.9.3 Bonding facilities2.11.2 Conduit entry3.3 Enclosures containing fuses3.4 Plugs and socket-outlets5.2.2 Drop test5.6 Thermal shock test

First published as AS 2238-1979.
Second edition 1982.
Revised and redesignated AS 2380.9-1991.

⚠

A newer version of this standard is available.

View Current Edition
$118.42
Including GST where applicable