Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 2464.3-1983

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Methods of testing thermal insulation Thermal resistance of low-density loose-fill insulation

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

04-07-1983

Superseded date

03-03-2024

Superseded by

AS/NZS 4859.1:2002

$47.81
Including GST where applicable

1 - AS 2464.3-1983 METHODS OF TESTING THERMAL INSULATION - THERMAL RESISTANCE OF LOW-DENSITY LOOSE-FILL INSULATION
1 - 1 SCOPE.
1 - 2 APPLICATION.
1 - 3 REFERENCED DOCUMENTS.
1 - 4 DEFINITIONS.
1 - 5 PRINCIPLE AND GENERAL CONSIDERATIONS.
1 - 5.1 Calculations on Installed Condition.
1 - 5.2 Thermal Conductance.
1 - 5.3 Thermal Resistance.
1 - 5.4 Homogeneity.
1 - 5.5 Normal Use.
2 - 5.6 Guarded Hotplate.
2 - 5.7 Heat Flow Meter.
2 - 5.8 Density Determination.
2 - 6 APPARATUS.
2 - 6.1 Configuration.
2 - 6.2 Size.
2 - 6.3 Heat Meter Placement and Configuration.
2 - 6.4 General Arrangement of Apparatus.
3 - 6.5 Temperature of Operation.
3 - 6.6 Heating and Cooling System Controls.
3 - 7 SAMPLE PREPARATION.
3 - 7.1. Selection.
3 - 7.2 Containment Frame.
3 - 7.3 Calculation of Mass.
3 - 7.4 Selection of Test Specimen.
4 - 7.5 Conditioning of Test Specimen.
4 - 7.6 Preparation of Test Specimen.
4 - 8 PROCEDURE.
4 - 9 CALCULATIONS.
4 - 9.1 Thermal Conductance.
5 - 9.2 Thermal Resistance.
5 - 10 REPORT.

AS 2464.3-1983 sets out a method of test to determine the thermal resistance of low-density fibrous loose-fill thermal insulation for use in the temperature range −18°C to 55°C.

Committee
BD-058
DocumentType
Standard
ISBN
0 7262 3015 4
Pages
5
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This standard sets out a method of test to determine the thermal resistance of low-density fibrous loose-fill thermal insulation for use in the temperature range -18C to 55C. It is primarily intended for use with pneumatically applied thermal insulation, but it may also be used with poured-in-place thermal insulation.

Under Revision See DR 02026 CP

AS 2464.2-1981 Methods of testing thermal insulation - Bulk density of blown fibrous loose-fill thermal insulation
AS 2464.5-1985 Methods of testing thermal insulation Steady-state thermal transmission properties by means of the heat flow meter
AS 2464.6-1983 Methods of testing thermal insulation - Steady-state thermal transmission properties by means of the guarded hot plate
AS 2352-1980 Glossary of terms for thermal insulation of buildings

AS 2461-1981 Mineral wool thermal insulation - Loose fill
AS 2463-1981 Sea grass bulk thermal insulation
AS 2462-1981 Cellulosic fibre thermal insulation

$47.81
Including GST where applicable