AS 2802-1992

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1992

Superseded date

22-05-2024

Superseded by

AS/NZS 2802:2000

$184.71
Including GST where applicable
Summarise this standard

Specifies the requirements for two classes of multicore elastomer insulated and sheathed flexible reeling and trailing cables for surface mining, underground mining (other than coal mining) and general use, where movable plant requires electricity supply at system voltages from 1.1/1.1 kV up to and including 33/33 kV.

Committee
EL-003
DocumentType
Standard
ISBN
0 7262 7243 4
Pages
48
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard specifies requirements for two classes of multicore elastomer insulated and sheathed flexible reeling and trailing cables for surface mining, underground mining (other than coal mining) and general use, where movable plant requires electricity supply at system voltages from 1.1/1.1 kV up to and including 33/33 kV.The Class 1 cables are insulated with a high grade ethylene propylene rubber (XR-EP-90) which permits a reduced radial thickness for the insulation and may provide a more flexible and more easily handled cable compared with equivalent rated Class 2 cables. The cable sheath is extra-heavy duty chlorosulphonated polyethylene, or chlorinated polyethylene (XHD-90-CSP, or CPE), or polychloroprene (XHD-85-PCP).The Class 2 cables are designed for manufacture using standard R-EP-90 insulation and HD-90-CSP, HD-90-CPE or HD-85-PCP sheath. The greater insulation radial thickness required for these cables provides a more robust cable.This Standard is intended to apply only to cables of the types provided for in the tables of construction and dimensions (Figures 3 to 8 and Tables 14 to 19).It is not intended, however, that the use of other types of cables should be precluded and regulatory authorities may give approval to new types as they are developed. Appropriate requirements for new types and sizes will eventually be included in this Standard as the need arises.This Standard also provides the basis of requirements for other sizes in the range of materials covered by this Standard.

First published as part of AS C81-1941.
Second edition 1950.
Third edition 1967.
Fourth edition 1973.
Revised and redesignated AS 1802-1976.
AS 1802-1976 withdrawn 1978.
AS 1802-1976 revised and redesignated in part as AS 2802-1985.
Second edition 1992.

⚠