Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 3653-1993

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Boilers - Safety, management, combustion and other ancillary equipment

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1993

Superseded date

25-07-2024

Superseded by

AS 2593-2004

$130.14
Including GST where applicable
Summarise this standard

1 - AS 3653-1993 BOILERS-SAFETY, MANAGEMENT, COMBUSTION AND OTHER ANCILLARY EQUIPMENT
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.5 IMPLEMENTATION
8 - SECTION 2 GENERAL VALVES, GAUGES AND OTHER FITTINGS
8 - 2.1 GENERAL REQUIREMENTS
8 - 2.1.1 Design and construction
8 - 2.1.2 Valve and fitting scantlings
8 - 2.1.3 Minimum requisite fittings
9 - 2.1.4 Accessibility
9 - 2.1.5 Screwed connections
11 - 2.1.6 Studs for fittings
11 - 2.2 STOP AND ISOLATING VALVES
11 - 2.2.1 Stop valves
11 - 2.2.2 Isolating valves
11 - 2.2.3 Valve type
11 - 2.3 BLOWDOWN AND DRAIN FACILITIES
11 - 2.3.1 General
11 - 2.3.2 Blowdown facilities
12 - 2.3.3 Drain facilities
12 - 2.4 PRESSURE GAUGES
12 - 2.4.1 General
12 - 2.4.2 Construction
12 - 2.4.3 Connections
12 - 2.4.4 Test pressure gauge attachment
13 - SECTION 3 SAFETY VALVES
13 - 3.1 SIZE, NUMBER AND LOCATION OF VALVES
13 - 3.2 DISCHARGE CAPACITY
13 - 3.2.1 Unvented systems
13 - 3.2.2 Open-vented systems
14 - 3.2.3 Integral superheater discharge capacity
14 - 3.2.4 Independently-fired superheater discharge capacity
14 - 3.2.5 Reheater discharge capacity
14 - 3.2.6 Economizer discharge capacity
14 - 3.3 ACCUMULATION
14 - 3.4 RESEATING PRESSURE
15 - 3.5 DISCHARGE TESTS AND SAFETY VALVES
15 - 3.6 TYPE AND MINIMUM SIZE OF VALVES
15 - 3.7 VALVE SETTINGS
15 - 3.8 CONNECTIONS TO SHELL
16 - 3.9 EXPANSION JOINTS
16 - 3.10 PILOT PIPES
16 - 3.11 SAFETY VALVE DISCHARGE SYSTEM
16 - 3.12 DISCHARGE RESTRICTION
17 - SECTION 4 WATER LEVEL MANAGEMENT AND SECURITY
17 - 4.1 WATER LEVEL DEVICES AND INTERLOCKS
17 - 4.1.1 General
17 - 4.1.2 Level alarms
17 - 4.1.3 Automatic water level controllers and interlocks
18 - 4.2 WATER LEVEL INDICATORS
18 - 4.2.1 Number and type
19 - 4.2.2 Length of gauge glass on boilers other than water-tube type
19 - 4.2.3 Glass diameter
19 - 4.2.4 Visibility and accessibility
19 - 4.2.5 Drains
20 - 4.2.6 Guards
20 - 4.2.7 Water level gauge connections and location
21 - 4.2.8 Connecting pipes for water gauges
22 - 4.2.9 Safety devices
22 - 4.3 FEED SYSTEMS
22 - 4.3.1 Design pressure
22 - 4.3.2 Design temperature
22 - 4.3.3 Feedwater arrangements
24 - SECTION 5 BOILER MANAGEMENT SYSTEMS
24 - 5.1 GENERAL
24 - 5.2 MANUAL OPERATION
24 - 5.3 AUTOMATIC OPERATION
24 - 5.3.1 General
24 - 5.3.2 Automatic water level management
24 - 5.3.3 Alarms
24 - 5.4 UNATTENDED AND LIMITED ATTENDANCE OPERATION
24 - 5.5 PLC MANAGEMENT SYSTEMS
25 - 5.6 ELECTRICAL EQUIPMENT
25 - 5.6.1 Electrical requirements
25 - 5.6.2 Control cabinets
26 - 5.7 NOTICES
27 - SECTION 6 ENERGY INPUT SYSTEMS
27 - 6.1 COMBUSTION SYSTEMS
27 - 6.1.1 Suitability
27 - 6.1.2 Combustion heat flux limitation
27 - 6.1.3 Automatic oil and gas firing equipment
27 - 6.1.4 Other oil, gas or solid-fuel-in-suspension firing equipment
27 - 6.1.5 Solid-fuel firing systems
28 - 6.1.6 Piping
28 - 6.2 WASTE HEAT ENERGY RECOVERY SYSTEM
28 - 6.2.1 Input control
28 - 6.2.2 Input location
28 - 6.3 ELECTRIC ENERGY INPUT SYSTEMS
28 - 6.3.1 General
28 - 6.3.2 Electricity supply
28 - 6.3.3 Load adjustment
29 - 6.3.4 Current balance
29 - 6.3.5 Electrodes, elements and internal parts
29 - 6.3.6 Pressure and temperature control
29 - 6.3.7 Access
30 - SECTION 7 INTEGRAL AND BOILER PRESSURE PIPING
30 - 7.1 GENERAL
30 - 7.2 WATER- HEATING BOILER SYSTEM DESIGN
30 - 7.2.1 General
30 - 7.2.2 Expansion vessels
30 - 7.2.3 Piping system
31 - 7.2.4 Make-up water systems
31 - 7.2.5 Energy input interlock
32 - APPENDIX A - LIST OF REFERENCED DOCUMENTS
34 - APPENDIX B - EXAMPLE OF INTEGRAL BOILER PIPING COVERED BY AS 1228 AND THIS STANDARD

Specifies requirements for components, ancillary equipment, and management systems used as part of the boiler pressure and energy-generating system, including combustion equipment, water level security, safety valves and other fittings, blowdown connections and integral piping. Most of the requirements in This Standard are currently in AS 1228, Boilers - Water-tube, and AS 1797, Boilers - Fire-tube, shell and miscellaneous, with some requirements similar in both Standards, while others are different. The requirements have been reviewed, and as far as practicable, uniform requirements have been proposed in This Standard which will be applicable to all types of boilers. It is intended that all such requirements shall be withdrawn from AS 1228 and AS 1797 at their next revision.

Committee
ME-001
DocumentType
Standard
ISBN
0 7262 8402 5
Pages
28
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard specifies the requirements for components, ancillary equipment and management systems used as a part of the boiler pressure and energy generating systems, including management systems, combustion equipment, water level security, safety valves, general valves and fittings, blowdown connections and integral piping.NOTE: Ancillary equipment and its installation, which form part of the support system, e.g. feed water supply, plant piping, and environmental equipment, are covered in AS 3892.This Standard is intended to-(a) establish the requirements for boiler management systems for all levels of automated operation, and to include controls, interlocks, electrical systems and other safety systems; (b) establish the minimum requisite fittings and valves such as safety valves and blowdown valves; (c) establish selection criteria for energy input equipment such as combustion equipment and the requirements for interfacing with the boiler design; and (d) form a bridge between the design codes (AS 1228, AS 1271, AS 1797) and AS 3892.

First published as AS 3653-1993.

⚠

A newer version of this standard is available.

View Current Edition
$130.14