Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Wiring Rules bundle. AS/NZS 3000 + 3008.1.1 with 10% off already included. Shop Now

AS 3703.2-1989

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Long-span corrugated steel structures - Design and installation

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1989

Superseded date

22-05-2024

$91.21
Including GST where applicable
Summarise this standard

1 - AS 3703.2-1989 LONG-SPAN CORRUGATED STEEL STRUCTURES - DESIGN AND INSTALLATION
4 - PREFACE
5 - CONTENTS
6 - SECTION 1. SCOPE AND GENERAL
6 - 1.1 SCOPE.
6 - 1.2 REFERENCED DOCUMENTS.
6 - 1.3 DEFINITION.
6 - 1.4 NOTATION
8 - SECTION 2. DESIGN
8 - 2.1 GENERAL.
8 - 2.2 GEOMETRIC LIMITS.
8 - 2.3 DESIGN FACTORS.
8 - 2.4 DESIGN SOIL COMPACTION.
9 - 2.5 DESIGN PRESSURE.
9 - 2.6 RING COMPRESSION.
9 - 2.7 STRESSES.
9 - 2.8 THICKNESS.
10 - 2.9 MINIMUM REQUIREMENTS.
10 - 2.9.1 Thickness.
10 - 2.9.2 Cover.
10 - 2.10 SEAM STRENGTH.
10 - 2.11 END TREATMENT.
10 - 2.11.1 General.
10 - 2.11.2 End stiffening collars.
12 - SECTION 3. INSTALLATION
12 - 3.1 GENERAL.
12 - 3.2 ASSEMBLY.
12 - 3.3 MINIMUM SPACING FOR MULTIPLE INSTALLATIONS.
12 - 3.4 METHOD OF INSTALLATION.
12 - 3.4.1 Installation in trench.
12 - 3.4.2 Installation in fill.
12 - 3.5 FOUNDATION PREPARATION.
12 - 3.5.1 Horizontal ellipses and inverted pear shapes.
12 - 3.5.2 High profile, low profile, and pear arches.
12 - 3.6 PLATE ASSEMBLY.
12 - 3.6.1 General.
12 - 3.6.2 Bolt torque.
12 - 3.6.3 Shape tolerances.
12 - 3.7 BACKFILLING.
12 - 3.7.1 Material.
12 - 3.7.2 Placement.
13 - 3.8 FINAL STRUCTURE SHAPE.
13 - 3.9 CORROSION PROTECTION.
14 - APPENDIX A - RAILWAY M250 LIVE LOAD * PLUS IMPACT PRESSURE ON THE STRUCTURE
15 - APPENDIX B - HIGHWAY T44-A14 LIVE LOAD * PLUS IMPACT PRESSURE ON THE STRUCTURE
16 - APPENDIX C - REFERENCE TABLES BASED ON RAILWAY LOADING (M250)
19 - APPENDIX D - REFERENCE TABLES BASED ON HIGHWAY LOADING (T44- A14)
22 - APPENDIX E - CORROSION OF CORRUGATED METAL STRUCTURES

Sets out requirements for the design and installation of long-span corrugated steel structures. Design requirements include soil compaction, design pressure, stresses, thickness of metal, seam strength and minima for metal thickness and cover. Installation requirements include foundation preparation, plate assembly, backfilling, and corrosion protection. Appendices tabulate cover limits and bolting for railway loading (M250) and highway loading (T44-A14) for the various structures.

Committee
CE-025
DocumentType
Standard
ISBN
0 7262 5821 0
Pages
17
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out requirements for a design method and the installation procedure for long-span corrugated steel structures with longitudinal stiffeners, including horizontal ellipses, inverted pear shapes, high profile arches, low profile arches, pear arches, and special shapes, having dimensions within the limits specified in Clause 2.2.This Standard does not cover the design of longitudinal stiffeners, footings, and end stiffening collars.NOTE: Requirements for the materials and manufacture of these structures are specified in AS 3703.1.

Under Revision se DR 02334 and DR 02335

⚠

A newer version of this standard is available.

View Current Edition View Current Edition
$91.21
Including GST where applicable