Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 3959-1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Construction of buildings in bushfire-prone areas

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

05-12-1999

Superseded date

29-07-2024

Superseded by

AS 3959-2009

$125.14
Including GST where applicable

1 - AS 3959:1999 CONSTRUCTION OF BUILDINGS IN BUSHFIRE-PRONE AREAS
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - SECTION 1 - SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 OBJECTIVE
7 - 1.3 APPLICATION
7 - 1.4 REFERENCED DOCUMENTS
8 - 1.5 DEFINITIONS
8 - 1.5.1 Bushfire
8 - 1.5.2 Bushfire attack
8 - 1.5.3 Bushfire-prone area
8 - 1.5.4 Combustible
8 - 1.5.5 Fire retardant
8 - 1.5.6 Fire-retardant-treated timber
9 - 1.5.7 Foliage cover
9 - 1.5.8 Non-combustible
9 - 1.5.9 Site
9 - 1.5.10 Wildfire
10 - SECTION 2 - SITE BUSHFIRE ATTACK ASSESSMENT
10 - 2.1 GENERAL
10 - 2.2 PROCEDURE
10 - 2.2.1 General
10 - 2.2.2 Predominant vegetation class
11 - 2.2.3 Distance from vegetation
11 - 2.2.4 Slope
13 - SECTION 3 - BUILDING CONSTRUCTION
13 - 3.1 GENERAL
13 - 3.2 LEVELS OF CONSTRUCTION
13 - 3.3 FLOORING SYSTEMS
13 - 3.3.1 Level 1 construction
14 - 3.3.2 Level 2 construction
14 - 3.3.3 Level 3 construction
15 - 3.4 SUPPORTING POSTS, COLUMNS, STUMPS, PIERS AND POLES
15 - 3.4.1 Level 1 construction
15 - 3.4.2 Level 2 construction
16 - 3.4.3 Level 3 construction
16 - 3.5 EXTERNAL WALLS
16 - 3.5.1 Level 1 construction
19 - 3.5.2 Level 2 construction
19 - 3.5.3 Level 3 construction
19 - 3.6 WINDOWS
19 - 3.6.1 Level 1 construction
19 - 3.6.2 Level 2 construction
19 - 3.6.3 Level 3 construction
19 - 3.7 EXTERNAL DOORS
19 - 3.7.1 Level 1 construction
19 - 3.7.2 Level 2 construction
20 - 3.7.3 Level 3 construction
20 - 3.8 VENTS AND WEEPHOLES
20 - 3.8.1 Level 1 construction
20 - 3.8.2 Level 2 construction
20 - 3.8.3 Level 3 construction
21 - 3.9 ROOFS
21 - 3.9.1 Level 1 construction
24 - 3.9.2 Level 2 construction
24 - 3.9.3 Level 3 construction
24 - 3.10 EAVES
24 - 3.10.1 Level 1 construction
24 - 3.10.2 Level 2 construction
24 - 3.10.3 Level 3 construction
24 - 3.11 FASCIAS
24 - 3.11.1 Level 1 construction
25 - 3.11.2 Level 2 construction
25 - 3.11.3 Level 3 construction
25 - 3.12 GUTTERS AND DOWNPIPES
25 - 3.12.1 Level 1 construction
25 - 3.12.2 Level 2 construction
25 - 3.12.3 Level 3 construction
25 - 3.13 VERANDAS AND DECKS
25 - 3.13.1 Level 1 construction
26 - 3.13.2 Level 2 construction
26 - 3.13.3 Level 3 construction
26 - 3.14 SERVICE PIPES (WATER AND GAS)
26 - 3.14.1 Level 1 construction
26 - 3.14.2 Level 2 construction
26 - 3.14.3 Level 3 construction
27 - APPENDIX A - HOW TO USE THIS STANDARD
27 - A1 GENERAL
27 - A2 BUSHFIRE-PRONE AREA
27 - A3 BUSHFIRE ATTACK
27 - A4 CONSTRUCTION
30 - APPENDIX B - DESIGNATION OF BUSHFIRE- PRONE AREAS BY VARIOUS AUTHORITIES
30 - B1 SCOPE
30 - B2 VICTORIA - ASSESSMENT OF BUSHFIRE-PRONE ZONES
31 - B3 NEW SOUTH WALES - ASSESSMENT OF BUSHFIRE-PRONE ZONES
31 - B4 SOUTH AUSTRALIA - BUSHFIRE HAZARD MAPPING
31 - B5 QUEENSLAND - BUSHFIRE RISK ANALYSIS METHODOLOGY
32 - APPENDIX C - INFORMATION ON BUILDING IN BUSHFIRE-PRONE AREAS
32 - C1 GENERAL
32 - C2 SITING
32 - C3 LANDSCAPING
32 - C4 MAINTENANCE
33 - APPENDIX D - BIBLIOGRAHY OF PUBLICATIONS FOR BUILDING IN BUSHFIRE-PRONE AREAS

Sets out requirements for the design and construction of buildings in bushfire-prone areas in order to improve their performance when they are subjected to burning debris, radiant heat or flame contact generated from a bushfire. Also includes a methodology for assessing categories of bushfire attack in respect of a site situated in an area that has been designated by a relevant authority as bushfire-prone.

Committee
FP-020
DocumentType
Standard
ISBN
0 7337 3049 3
Pages
27
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for the design and construction of buildings in bushfire-prone areas in order to improve their performance when subjected to burning debris, radiant heat or flame contact generated from a bushfire.

First published as AS 3959-1991.
Second edition 1999.

AS 1684.3-2006 Residential timber-framed construction Cyclonic areas
AS 1530.2-1993 Methods for fire tests on building materials, components and structures Test for flammability of materials (Reconfirmed 2016)
AS/NZS 3837:1998 Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter (Reconfirmed 2016)
AS/NZS 4200.1:1994 Pliable building membranes and underlays Materials
AS 1530.1-1994 Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016)
AS/NZS 1530.3:1999 Methods for fire tests on building materials, components and structures Simultaneous determination of ignitability, flame propagation, heat release and smoke release (Reconfirmed 2016)
AS 4285-2007 Skylights
AS 1288-2006 Glass in buildings - Selection and installation
AS 1684.2-2006 Residential timber-framed construction Non-cyclonic areas (SEE IMPORTANT NOTE)
AS 3660.1-2000 Termite management New building work

HB 37.4-1994 Handbook of Australian fire Standards Building materials, products and construction
AS 1530.8.2-2007 Methods for fire tests on building materials, components and structures Tests on elements of construction for buildings exposed to simulated bushfire attack - Large flaming sources
AS 1530.8.1-2007 Methods for fire tests on building materials, components and structures Tests on elements of construction for buildings exposed to simulated bushfire attack - Radiant heat and small flaming sources
AS/NZS 4200.2:1994 Pliable building membranes and underlays Installation requirements
AS 4285-2007 Skylights
HB 125-2007 The glass and glazing handbook (including guide to AS 1288, Glass in buildings - Selection and installation)

$125.14
Including GST where applicable