Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 4085-1992

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Automatic sliding door assemblies

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1992

Superseded date

30-06-2017

Superseded by

AS 5007-2007

$114.35
Including GST where applicable
Summarise this standard

1 - AS 4085:1992 AUTOMATIC SLIDING DOOR ASSEMBLIES
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 - SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 REFERENCED DOCUMENTS
6 - 1.4 DEFINITIONS
6 - 1.4.1 Actuator
6 - 1.4.2 Clear opening
6 - 1.4.3 Detector
6 - 1.4.4 Detection zone
7 - 1.4.5 Door
7 - 1.4.6 Door hardware
7 - 1.4.7 Door leaf
7 - 1.4.8 Door set
7 - 1.4.9 Emergency condition
7 - 1.4.10 Failsafe
7 - 1.4.11 Frame
7 - 1.4.12 Framed door
7 - 1.4.13 Fully open
7 - 1.4.14 Guides
7 - 1.4.15 Hangers
7 - 1.4.16 Leading edge
7 - 1.4.17 Lintel
7 - 1.4.18 Loading
7 - 1.4.19 Mullion
7 - 1.4.20 Operator
7 - 1.4.21 Operating cycle
7 - 1.4.22 Overall opening
7 - 1.4.23 Pelmet
7 - 1.4.24 Permanent frame
7 - 1.4.25 Transom assembly
7 - 1.4.26 Trailing edge
7 - 1.4.27 Unframed door
7 - 1.4.28 Velocity
8 - 1.5 DUTY RATING
9 - SECTION 2 - DOOR SETS
9 - 2.1 MATERIALS
9 - 2.1.1 General
9 - 2.1.2 Aluminium
9 - 2.1.3 Glass
9 - 2.1.4 Steel
9 - 2.1.5 Timber
9 - 2.2 LOADS
9 - 2.2.1 General
9 - 2.2.2 Vertical loads
9 - 2.2.3 Lateral loads
9 - 2.2.4 Racking loads
9 - 2.3 PERMANENT FRAME AND SUPPORT SYSTEMS
9 - 2.3.1 General
10 - 2.3.2 Fixings
10 - 2.3.3 Mullions
10 - 2.3.4 Lintels
10 - 2.3.5 Operators and transom assemblies
10 - 2.3.6 Fixed panels
10 - 2.4 DOORS AND DOOR HARDWARE
10 - 2.4.1 General
10 - 2.4.2 Door leaf frames
12 - 2.4.3 Hangers
12 - 2.4.4 Bottom guides
12 - 2.4.5 Door hardware
12 - 2.4.6 Indicator sign
13 - 2.5 OPERATION
13 - 2.5.1 General
13 - 2.5.2 Limits of travel
14 - SECTION 3 - ACTUATORS
14 - 3.1 PERFORMANCE CHARACTERISTICS
14 - 3.1.1 General
14 - 3.1.2 Kinetic energy limitation
14 - 3.1.3 Holding force
14 - 3.1.4 Ambient conditions
14 - 3.2 INSTALLATION
14 - 3.2.1 General
14 - 3.2.2 Electrical installation
15 - SECTION 4 - DETECTORS
15 - 4.1 DETECTOR FUNCTIONS
15 - 4.1.1 General
15 - 4.1.2 Detector types
15 - 4.1.3 Detection zone
15 - 4.2 PRESSURE MATS
15 - 4.2.1 Materials
15 - 4.2.2 Detection zone
15 - 4.2.3 Performance characteristics
15 - 4.2.4 Installation
15 - 4.3 PHOTO-ELECTRIC DETECTORS
15 - 4.3.1 General
15 - 4.3.2 Detection zone
16 - 4.3.3 Performance characteristics
16 - 4.3.4 Installation
16 - 4.4 RADIANT ENERGY DETECTORS
16 - 4.4.1 General
16 - 4.4.2 Detection zone
17 - 4.4.3 Performance characteristics
17 - 4.4.4 Installation
17 - 4.4.4.1 Physical
17 - 4.4.4.2 Electrical
17 - 4.5 SAFETY DETECTORS
18 - SECTION 5 - CONTROL SYSTEMS
18 - 5.1 GENERAL
18 - 5.2 OPERATING REQUIREMENTS
18 - 5.3 REQUIRED EXIT DOORS
18 - 5.3.1 Application
18 - 5.3.2 Operation
18 - 5.3.3 Low battery warning device
18 - 5.4 SECURITY CONTROL
19 - SECTION 6 - INSTALLATION AND COMMISSIONING
19 - 6.1 GENERAL
19 - 6.2 INSTALLATION OF COMPONENTS
19 - 6.2.1 Permanent frame
19 - 6.2.2 Operator
19 - 6.2.3 Fixed panels
19 - 6.2.4 Doors
19 - 6.2.5 Bottom guides
19 - 6.2.6 Other components
19 - 6.3 ELECTRICAL INSTALLATION
19 - 6.3.1 General
19 - 6.3.2 Wiring recommendations
19 - 6.3.3 Building emergency alarm system
19 - 6.4 COMMISSIONING
19 - 6.4.1 Adjustment of components
20 - 6.4.2 Commissioning operation
20 - 6.4.3 Commissioning report
20 - 6.4.4 System identification
21 - APPENDIX A - RECOMMENDED AUTOMATIC SLIDING DOOR INSPECTION AND MAINTENANCE PROCEDURES
21 - A1 INTRODUCTION
21 - A2 OPERATIONAL INSPECTION AND MAINTENANCE
21 - A2.1 General
21 - A2.2 Inspection and maintenance frequency
21 - A2.3 Inspection procedure
21 - A3 LOG BOOK
21 - A4 MAINTENANCE PERSONNEL
22 - A5 INSPECTION REPORT

Specifies minimum performance requirements for materials and components of automatic sliding doors and door assemblies. Information is provided on operational safety and durability for ingress and egress traffic when assembled, installed and commissioned. Doors are classified according to hourly operating cycles. Control systems are described for both normal and emergency conditions including positioning and operation of pressure mats, photo-electric and radiant energy detectors as well as detection zone dimensions. An Appendix introduces recommended operational inspection procedures and frequency.

Committee
BD-055
DocumentType
Standard
ISBN
0 7262 7891 2
Pages
17
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out functional requirements for the materials and components of automatic sliding door assemblies and requirements for operational safety and durability when assembled, installed, and commissioned. The Standard also classifies sliding doors in accordance with a duty rating according to the expected average number of operational cycles.NOTE: Appendix A describes recommended automatic sliding door inspection and maintenance procedures.

First published as AS 4085-1992.

⚠

A newer version of this standard is available.

View Current Edition
$114.35
Including GST where applicable