AS 4180.1-1994

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Drift loss from cooling towers - Laboratory measurement - Chloride balance method

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1994

Superseded date

17-05-2018

Superseded by

AS 4180.1-2008

$63.00
Including GST where applicable

1 - AS 4180.1:1994 DRIFT LOSS FROM COOLING TOWERS - LABORATORY MEASUREMENT - CHLORIDE BALANCE METHOD
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - 1 SCOPE
7 - 2 APPLICATION
7 - 3 REFERENCED DOCUMENTS
7 - 4 DEFINITIONS
7 - 4.1 Circulating water temperature
7 - 4.2 Clean
7 - 4.3 Cooling tower
7 - 4.4 Drift
8 - 4.5 Drift loss mass flow rate
8 - 4.6 Dry bulb temperature
8 - 4.7 Effective wet bulb depression
8 - 4.8 Water mass flow rate
8 - 4.9 Wet bulb depression
8 - 4.10 Wet bulb temperature
8 - 5 GENERAL REQUIREMENTS FOR EQUIPMENT TESTED
8 - 5.1 General
8 - 5.2 Device under test
8 - 5.3 Water leaks
8 - 6 REQUIRED TEST CONDITIONS
8 - 6.1 General
9 - 6.2 Flow rates
9 - 6.3 Wind velocity
9 - 6.4 Rain
9 - 6.5 Test temperatures
9 - 6.6 Water samples
9 - 7 SODIUM CHLORIDE REQUIREMENTS
9 - 7.1 General
9 - 7.2 Sodium chloride mass
9 - 7.3 Accuracy
9 - 7.4 Sodium chloride solution
9 - 8 CHLORIDE ION CONCENTRATION MEASUREMENT
9 - 8.1 Samples
9 - 8.2 Measurement
10 - 9 TEST PROCEDURE
11 - 10 CALCULATIONS
11 - 10.1 Circulating water
11 - 10.2 Drift measurement time
11 - 10.3 Mass of sodium chloride
11 - 10.4 Mean effective wet bulb
11 - 10.5 Evaporation ratio
11 - 10.6 Drift loss
11 - 10.7 Percentage drift loss
12 - 11 TEST REPORT
13 - APPENDIX A - NOMENCLATURE
14 - APPENDIX B - SAMPLE CALCULATIONS
14 - B1 GENERAL
14 - B2 INITIAL MEASUREMENTS
14 - B3 MASS OF SODIUM CHLORIDE
14 - B4 MAKE-UP WATER TIME
14 - B5 DRIFT TIME
14 - B6 SAMPLE READINGS
15 - B7 WATER MASS
15 - B8 CHECK DRIFT TIME
15 - B9 CHECK SALT MASS
15 - B10 EVAPORATION RATIO
16 - B11 DRIFT LOSS RATE
16 - B12 PERCENTAGE DRIFT LOSS
17 - APPENDIX C - SUGGESTED EQUIPMENT

Sets out the requirements necessary to obtain measurements of drift of circulatory water into the atmosphere from a cooling tower, by a chloride ion mass balance on the water circuit, under laboratory conditions.

Committee
ME-062
DocumentType
Standard
ISBN
0 7262 8795 4
Pages
11
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out the requirements necessary to obtain measurements of drift of circulating water into the atmosphere, by a chloride ion mass balance on the water circuit, under laboratory conditions.

First published as AS 4180.1-1994.

AS 2360.1.4-1993 Measurement of fluid flow in closed conduits Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Guide to the effect of departure from the conditions specified in Pt 1.1
AS 2360.1.3-1993 Measurement of fluid flow in closed conduits Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Guide to the use of methods specified in Parts 1.1 and 1.2
AS 2360.1.2-1993 Measurement of fluid flow in closed conduits Pressure differential methods - Measurement using orifice plates or nozzles - Conduits with diameters less than 50 mm
AS 2031.1-1986 Selection of containers and preservation of water samples for chemical and microbiological analysis - Chemical
AS 2093-1977 Salt for use in the manufacture of dairy products
AS 2360.1.1-1993 Measurement of fluid flow in closed conduits Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Conduits with diameters from 50 mm to 1200 mm
AS 3666-1989 Air-handling and water systems of buildings - Microbial control

AS/NZS 3666.1:2002 Air-handling and water systems of buildings - Microbial control Design, installation and commissioning
SAA/SNZ HB32:1995 Control of microbial growth in air-handling and water systems in buildings (Reconfirmed 2016)
AS/NZS 3666.1:1995 Air-handling and water systems of buildings - Microbial control Design, installation and commissioning

$63.00