Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 4332-1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

The storage and handling of gases in cylinders

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1995

Superseded date

29-07-2024

Superseded by

AS 4332-2004

$154.97
Including GST where applicable
Summarise this standard

1 - AS 4332-1995 THE STORAGE AND HANDLING OF GASES IN CYLINDERS
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
8 - 1.3 NEW DESIGNS AND INNOVATIONS
8 - 1.4 REFERENCED DOCUMENTS
8 - 1.5 DEFINITIONS
8 - 1.5.1 Access
8 - 1.5.2 Approved, approval
8 - 1.5.3 Asphyxia
8 - 1.5.4 Asphyxiant
8 - 1.5.5 Combustible materials
8 - 1.5.6 Cylinder
8 - 1.5.7 Fire damper
9 - 1.5.8 Fire-resistance level (FRL)
9 - 1.5.9 Flammable
9 - 1.5.10 Flammable (explosive) range
9 - 1.5.11 Flammable limits
9 - 1.5.12 Hazardous area
9 - 1.5.13 Ignition source
9 - 1.5.14 Incompatible
9 - 1.5.15 Liquefied gas
9 - 1.5.16 Material safety data sheet (MSDS)
9 - 1.5.17 Minor storage
9 - 1.5.18 On-site facilities
9 - 1.5.19 Pneumatic shock (adiabatic compression)
10 - 1.5.20 Practicable
10 - 1.5.21 Protected places
10 - 1.5.22 Regulator
10 - 1.5.23 Regulatory authority
10 - 1.5.24 Restricted area
10 - 1.5.25 Screen wall
10 - 1.5.26 Segregation
10 - 1.5.27 Separation
10 - 1.5.28 Static electricity
10 - 1.5.29 Transit storage
10 - 1.5.30 Vapour barrier
10 - 1.5.31 Water capacity (WC)
10 - 1.6 CLASSIFICATION
11 - 1.7 MARKING
11 - 1.8 SECURITY OF STORAGE AREAS
12 - SECTION 2 MINOR STORAGE
12 - 2.1 SCOPE OF SECTION
12 - 2.2 CRITERIA FOR CLASSIFICATION AS MINOR STORAGE
12 - 2.3 MINOR STORAGE OF MIXED GASES
12 - 2.4 PRECAUTIONS FOR THE STORAGE OF GASES IN MINOR QUANTITIES
13 - 2.5 OUTDOOR STORAGE
13 - 2.6 INDOOR STORAGE
13 - 2.7 FIRST AID
13 - 2.8 FIRE PROTECTION FOR MINOR STORES
13 - 2.8.1 Fire protection equipment
14 - 2.8.2 Action in the event of fire
15 - SECTION 3 TRANSIT STORAGE
15 - 3.1 SCOPE OF SECTION
15 - 3.2 DELINEATION OF TRANSIT STORAGE AREAS
15 - 3.3 REQUIREMENTS FOR TRANSIT STORAGE
16 - SECTION 4 CONSTRUCTION AND LOCATION OF STORES
16 - 4.1 SCOPE OF SECTION
16 - 4.2 TYPES OF STORES
16 - 4.3 REQUIREMENTS FOR THE CONSTRUCTION OF STORES
17 - 4.4 VENTILATION OF INDOOR STORES
17 - 4.4.1 General
17 - 4.4.2 Natural ventilation
18 - 4.4.3 Mechanical ventilation
20 - 4.5 SEPARATION AND SEGREGATION
20 - 4.5.1 General
20 - 4.5.2 Separation
20 - 4.5.3 Segregation
22 - SECTION 5 OPERATIONAL AND PERSONNEL SAFETY
22 - 5.1 SCOPE OF SECTION
22 - 5.2 PRECAUTIONS
22 - 5.2.1 General precautions
23 - 5.2.2 Precautions for flammable gases
23 - 5.2.3 Precautions for oxidizing gases
24 - 5.2.4 Precautions for toxic gases
24 - 5.2.5 Precautions for refrigerated and cryogenic gases
24 - 5.2.6 Precautions for acetylene
25 - 5.2.7 Control of entry
25 - 5.2.8 Clear access
25 - 5.2.9 Lighting
25 - 5.3 PERSONNEL TRAINING
25 - 5.3.1 Job knowledge
25 - 5.3.2 Training
25 - 5.3.3 Contractors
26 - 5.3.4 Retraining of personnel
26 - 5.4 PERSONAL PROTECTIVE EQUIPMENT
26 - 5.4.1 General
26 - 5.4.2 Types of personal protective equipment
26 - 5.4.3 Occasions for use of personal protective equipment
26 - 5.4.4 Care and maintenance of personal protective equipment
26 - 5.5 FIRST AID
26 - 5.5.1 First aid station
26 - 5.5.2 Safety shower and eye-wash facilities
26 - 5.5.3 First aid procedures
27 - SECTION 6 EMERGENCY MANAGEMENT
27 - 6.1 SCOPE OF SECTION
27 - 6.2 PLANNING FOR EMERGENCIES
27 - 6.2.1 Considerations in designing premises
27 - 6.2.2 Emergency plan
28 - 6.3 MANIFEST
28 - 6.4 PLACARDING
28 - 6.4.1 Placarding of stores
28 - 6.4.2 Safety information board
28 - 6.5 MANAGEMENT OF LEAKS
29 - SECTION 7 FIRE PROTECTION
29 - 7.1 SCOPE OF SECTION
29 - 7.2 APPLICATION
29 - 7.3 GENERAL CONSIDERATIONS
29 - 7.3.1 Hazards
29 - 7.3.2 Design and compatibility
29 - 7.3.3 Fire protection
30 - 7.3.4 Heat protection
30 - 7.3.5 Integration with existing facilities
30 - 7.3.6 Location
30 - 7.3.7 Weather protection
30 - 7.3.8 Fixed fire protection and detection systems
30 - 7.3.9 Fire alarm systems
31 - 7.4 FIRE EXTINGUISHERS
31 - 7.4.1 General
31 - 7.4.2 Location
31 - 7.4.3 Maintenance
31 - 7.4.4 Limitations
31 - 7.4.5 Rating
31 - 7.5 HOSE REELS
31 - 7.5.1 General
31 - 7.5.2 Location
31 - 7.5.3 Maintenance
31 - 7.6 FIRE HYDRANTS
31 - 7.6.1 General
32 - 7.6.2 Location
32 - 7.6.3 Maintenance
32 - 7.7 MONITORS
32 - 7.8 SPRINKLER SYSTEMS
32 - 7.8.1 General
32 - 7.8.2 Maintenance
32 - 7.9 WATER SUPPLY
33 - 7.10 FIRE PROTECTION REQUIREMENTS
33 - 7.11 ACTION IN THE EVENT OF FIRE
34 - SECTION 8 DISPOSAL OF CYLINDERS
34 - 8.1 SCOPE OF SECTION
34 - 8.2 DISPOSAL OF UNDAMAGED CYLINDERS
34 - 8.3 DISPOSAL OF DAMAGED, CORRODED OR LEAKING CYLINDERS
35 - APPENDIX A - HAZARDS ASSOCIATED WITH THE STORAGE AND HANDLING OF GASES
35 - A1 PRESSURE
35 - A2 FLAMMABILITY
36 - A3 REACTIVITY
36 - A4 TOXICITY
36 - A5 ASPHYXIANT HAZARD
36 - A6 OXYGEN-ENRICHED ATMOSPHERES
36 - A7 COLD HAZARD
38 - APPENDIX B - LIST OF REFERENCED DOCUMENTS
41 - APPENDIX C - CYLINDER DESIGNATIONS AND NOMINAL WATER CAPACITIES
41 - C1 CYLINDER CAPACITIES
41 - C2 CYLINDER SIZES
42 - APPENDIX D - MANAGEMENT OF LEAKS
43 - APPENDIX E - BIBLIOGRAPHY OF DOCUMENTS PROVIDING GUIDELINES ON THE PREPARATION OF EMERGENCY PLANS
44 - APPENDIX F - INFORMATION TO BE PROVIDED TO EMERGENCY SERVICES
45 - APPENDIX G - ACTION IN THE EVENT OF FIRE

Sets out requirements and recommendations for the storage and handling, in cylinders, of gases that are classified in the ADG Code as dangerous goods of Class 2. The Standard applies to stores in which individual gases, other than those which are dealt with in other Australian Standards, are kept, and to all stores in which more than one type of gas is kept. A bibliography of documents providing guidelines on the preparation of emergency plans is provided in an appendix.

Committee
CH-009
DocumentType
Standard
ISBN
0 7337 0010 1
Pages
39
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out requirements and recommendations for the safe storage and handling, in cylinders, of gases that are classified as Class 2 substances in the ADG Code (i.e. gases that are compressed, liquefied or dissolved under pressure, including refrigerated liquefied gases, mixtures of one or more gases with vapours or liquids of substances of other classes, articles charged with a gas and aerosols having a capacity of greater than 1 L). The Standard applies to all locations; however, they will generally be industrial, commercial or rural in nature.This Standard only applies to the storage of gases in cylinders, where those cylinders are not connected to any system intended for the transport, filling or consumption of the gas.The Standard does not apply to gases in dewar flasks, drums, or any containers not covered by the AS 2030 series of Standards.Residential premises storing less than 10% of the maximum quantities allowable for minor storage shall be exempt from the requirements of this Standard.For the purposes of this Standard, all cylinders shall be regarded as full unless gas-freed by the manufacturer or not containing a valve.NOTES:1 Advice supplementary to that provided in this Standard may need to be sought from the supplier of the goods.2 A discussion of the hazards presented by gases during their storage and handling is provided in Appendix A.

First published as AS 4332-1995.

⚠

A newer version of this standard is available.

View Current Edition
$154.97
Including GST where applicable