Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 4747.2-2013

Current

Current

The latest, up-to-date edition.

Meters for non-urban water supply Technical requirements for closed conduit meters fully charged

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

21-02-2013

$141.91
Including GST where applicable

Sets out requirements for water meters for use in non-urban applications. It primarily covers metering for irrigation water; however, it is intended that it be used for non-urban water applications other than applications covered by AS3565.1.

Committee
CE-024
DocumentType
Standard
ISBN
978 1 74342 353 0
Pages
30
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out requirements for water meters for use in non-urban applications. It primarily covers metering for irrigation water; however, it is intended that it be used for non-urban water applications other than applications covered by AS 3565.1.Two types of meters are covered in this Standard, as follows:(a)A ‘self-contained unit’—a meter that defines its own geometry, is able to be pattern-approved as a complete water meter, calibrated upon assembly and supplied by a single supplier.(b)A ‘modular metering system’—a device or group of instruments (which may be supplied as a pattern-approved metering system,) that does not define the installation geometry and requires configuration after installation.NOTES: 1The requirements for these types of meters to demonstrate compliance with this Standard, and hence with the National Framework are described in Section 4 and illustrated in Figure 4.1.2Purchasing guidelines are given in Appendix A.This Standard applies to meters that are—(i)self-contained or modular and capable of continuously determining, within the accuracy limits, the volume of water that has flowed through them; and(ii)continuously updating the volume on a cumulative basis.NOTE: In this Standard a meter installation is considered to include—(a)the meter, its indicating device and all ancillary equipment; and(b)the upstream and downstream pipe or emplacement that may have a material effect on the meter unit.This Standard applies to meters that operate under the following conditions:(A)Closed conduit under full flow.(B)Pressure ranges minimum 0.03 MPa to a value specified by the manufacturer. As a minimum, insertion or clamp-on meters will need to have the same working pressure range as the pipes they are designed to operate in.(C)Working water temperature range of 0.1°C to 30°C. The maximum admissible temperature is 50°C, which is the limiting condition for the meter.(D)Ambient air temperature range of ?5°C to 55°C.(E)Ambient humidity range of 0% to 100% except for remote indicating devices where the range is 0% to 93%.

First published as ATS 4747.2-2008.
Revised and redesignated as AS 4747.2-2013.

AS 1722.2-1992 Pipe threads of Whitworth form Fastening pipe threads (Reconfirmed 2017)
AS 4747.5-2013 Meters for non-urban water supply Installation and commissioning of closed conduit meters fully charged
AS 1565-1996 Copper and copper alloys - Ingots and castings (Reconfirmed 2020)
ATS 4747.1-2008 Meters for non-urban water supply Glossary of terms
AS 2345-2006 Dezincification resistance of copper alloys (Reconfirmed 2016)
AS 4747.6-2013 Meters for non-urban water supply Installation and commissioning of open channel meters
AS 3778.1-2009 Measurement of water flow in open channels Hydrometric determinations - Vocabulary and symbols
AS 4747.8-2013 Meters for non-urban water supply In-service compliance for non-urban water meters
AS 4747.3-2013 Meters for non-urban water supply Technical requirements for open channel meters
AS 4747.1-2013 Meters for non-urban water supply Glossary of terms
AS 2129-2000 Flanges for pipes, valves and fittings (Reconfirmed 2016)
AS/NZS 1567:1997 Copper and copper alloys - Wrought rods, bars and sections (Reconfirmed 2021)
AS 4087:2011 Metallic flanges for waterworks purposes
AS 2738-2000 Copper and copper alloys - Compositions and designations of refinery products, wrought products, ingots and castings (Reconfirmed 2018)
AS 3558.5-1999 Methods of testing plastics and composite materials sanitary plumbing fixtures Determination of degradation by ultraviolet light (Reconfirmed 2016)

AS 4747.6-2013 Meters for non-urban water supply Installation and commissioning of open channel meters
AS 4747.1-2013 Meters for non-urban water supply Glossary of terms
AS 4747.8-2013 Meters for non-urban water supply In-service compliance for non-urban water meters
AS 4747.3-2013 Meters for non-urban water supply Technical requirements for open channel meters
AS 4747.5-2013 Meters for non-urban water supply Installation and commissioning of closed conduit meters fully charged

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

$141.91
Including GST where applicable