Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 7240.8-2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire detection and alarm systems Carbon monoxide fire detectors using an electro-chemical cell in combination with a heat sensor

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

09-10-2007

Superseded date

02-03-2023

Superseded by

AS ISO 7240.8:2018

$184.51
Including GST where applicable

1 - AS 7240.8-2007 Fire detection and alarm systems Part 8: Carbon monoxide fire detectors using an electro-chemical cell in combination with a heat sensor
4 - PREFACE
5 - CONTENTS
8 - Introduction
9 - 1 Scope
9 - 2 Normative references
10 - 3 Definitions
10 - 4 General requirements
10 - 4.1 Compliance
10 - 4.2 Individual alarm indication
10 - 4.3 Connection of ancillary devices
10 - 4.4 Monitoring of detachable detectors
10 - 4.5 Manufacturer's adjustments
11 - 4.6 On- site adjustment of response behaviour
11 - 4.7 Rate- sensitive response behaviour
11 - 4.8 Marking
12 - 4.9 Data
12 - 4.10 Requirements for software controlled detectors
13 - 5 Tests
13 - 5.1 General
16 - 5.2 Repeatability of CO response
16 - 5.3 Directional dependence of CO response
17 - 5.4 Directional dependence of heat response
19 - 5.5 Lower limit of heat sensitivity
19 - 5.6 Reproducibility of CO response
19 - 5.6.1 Object of the test
20 - 5.7 Reproducibility of heat response
20 - 5.8 Exposure to chemical agents at environmental concentrations
21 - 5.9 Long- term stability of CO response
22 - 5.10 Saturation
22 - 5.11 Exposure to chemical agents that can be present during a fire
23 - 5.12 Variation in supply parameters
24 - 5.13 Air movement
25 - 5.14 Dry heat ( operational)
25 - 5.15 Cold ( operational)
26 - 5.16 Damp heat, cyclic ( operational)
28 - 5.17 Damp heat, steady state ( endurance)
29 - 5.18 Low humidity, steady state ( endurance)
29 - 5.19 Sulfur dioxide ( SO2) corrosion ( endurance)
30 - 5.20 Shock ( operational)
32 - 5.21 Impact ( operational)
33 - 5.22 Vibration, sinusoidal ( operational)
34 - 5.23 Vibration, sinusoidal ( endurance)
35 - 5.24 Electromagnetic compatibility ( EMC), immunity tests ( operational)
36 - 5.25 Fire sensitivity
38 - 6 Test report
39 - Annex A (normative) Gas test chamber for response threshold value and cross sensitivity measurements
40 - Annex B (normative) Heat tunnel for response time and response temperature measurements
41 - Annex C (normative) Apparatus for impact test
43 - Annex D (normative) Fire test room
45 - Annex E (normative) Smouldering (pyrolysis) wood fire (TF2)
48 - Annex F (normative) Glowing smouldering cotton fire (TF3)
51 - Annex G (normative) Open plastics (polyurethane) fire (TF4)
53 - Annex H (normative) Liquid (heptane) fire (TF5)
55 - Annex I (normative) Deep-seated smouldering cotton fire (TF9)
57 - Annex J (informative) Information concerning the construction of the gas test chamber
59 - Annex K (informative) Construction of the heat tunnel

Specifies requirements, test methods and performance criteria for point multisensor fire detectors that incorporate an electro-chemical cell for sensing CO in combination with one or more heat sensors.

Committee
FP-002
DocumentType
Standard
ISBN
0 7337 8405 4
Pages
53
PublisherName
Standards Australia
RevisionOf
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
ISO 7240-8:2007 Identical

First published as AS 7240.8-2007.

AS 60068.1-2003 Environmental testing General and guidance (Reconfirmed 2018)
AS 7240.5-2004 Fire detection and alarm systems Point type heat detectors (ISO 7240-5:2003, MOD) (Reconfirmed 2016)
AS 60068.2.78-2003 Environmental testing Tests - Test Cab: Damp heat, steady state (Reconfirmed 2018)
AS 60068.2.27-2003 Environmental testing Tests - Test Ea and guidance: Shock
AS 60068.2.6-2003 Environmental testing Tests - Test Fc: Vibration (sinusoidal) (Reconfirmed 2018)
AS 7240.1-2007 Fire detection and alarm systems - General and definitions
AS 60068.2.42-2004 Environmental testing Tests - Test Kc: Sulphur dioxide test for contacts and connections (Reconfirmed 2018)
AS 60068.2.1-2003 Environmental testing Tests - Test A: Cold (Reconfirmed 2018)
AS 7240.6-2006 Fire detection and alarm systems Carbon monoxide fire detectors using electro-chemical cells (Reconfirmed 2016)
AS 60068.2.2-2003 Environmental testing Tests - Test B: Dry heat (Reconfirmed 2018)
AS 60068.2.30-2003 Environmental testing Tests - Test Db and guidance: Damp heat, cyclic (12 + 12-hour cycle)

AS 7240.20-2012 Fire detection and alarm systems Aspirating smoke detectors (Reconfirmed 2023)
AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

$184.51
Including GST where applicable