AS/NZS 4234:2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Heated water systems - Calculation of energy consumption

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

21-08-2008

Superseded date

25-06-2026

Superseded by

AS/NZS 4234:2021

$177.64
Including GST where applicable
Summarise this standard

Sets out a method of evaluating the annual energy performance of water heaters using a combination of test results for component performance and a mathematical model to determine the standardized annual purchased energy use. The procedure is applicable to electric, gas and solar water heaters with integral boosting or preheating into a conventional storage or instantaneous water heater and to heat pump water heaters. For solar and heat pump water heaters, displaced purchased energy relative to reference water heaters is also calculated.

Committee
CS-028
DocumentType
Standard
ISBN
0 7337 8872 6
Pages
73
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out a method of evaluating the annual energy performance of water heaters using a combination of test results for component performance and a mathematical model to determine the standardized annual purchased energy use. The procedure is applicable to electric, gas and solar water heaters with integral boosting or preheating into a conventional storage or instantaneous water heater and to heat pump water heaters. For solar and heat pump water heaters, displaced purchased energy relative to reference water heaters is also calculated. Solar and solar boosted heat pump water heater types not covered in the application of this Standard can be tested under AS 2984 to obtain an annual performance assessment.There are no product design or operation requirements in this Standard. System operating parameters specified in this Standard are only for the purpose of performance modelling.

Originated as AS4234-1994.
Jointly revised and designated AS/NZS4234:2008.
Reissued incorporating Amendment No. 1 (March 2011).
Reissued incorporating Amendment No. 2 (November 2011).
Reissued incorporating Amendment No. 3 (November 2014).

⚠

A newer version of this standard is available.