AS/NZS 4695.2.2:1996
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire hazard testing of electrotechnical products Test methods - Needle-flame test
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
05-04-1996
30-06-2017
Specifies a needle-flame test to simulate the effect of small flames which may result from fault conditions within the equipment, in order to assess by a simulation technique the fire hazard. It is applicable to electrotechnical equipment, its subassemblies and components and to solid electrical insulating materials or other combustible materials. This Standard is technically equivalent to and reproduced from IEC 695-2-2:1991.
| Committee |
EL-002
|
| DocumentType |
Standard
|
| ISBN |
0 7337 0364 X
|
| Pages |
13
|
| PublisherName |
Standards Australia
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This section of IEC 695 specifies a needle-flame test to simulate the effect of small flames which may result from fault conditions within the equipment, in order to assess by a simulation technique the fire hazard.It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating materials or other combustible materials.
| Standards | Relationship |
| IEC 60695-2-2:1991 | Identical |
First published in Australia as part of AS 2420-1980.
Second edition 1983.
Third edition 1987.
First published in New Zealand as part of AS 2420-1987.
Jointly revised and redesignated in part as AS/NZS 4695.2.2:1996.
A newer version of this standard is available.
View Current Edition