AS/NZS 61241.4:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical apparatus for use in the presence of combustible dust Type of protection 'pD'
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
11-03-2002
12-05-2022
Specifies the requirements for design, construction, testing and marking of electrical apparatus, with type of protection pressurization 'pD', intended for use in combustible dust atmospheres. This Standard is identical with and has been reproduced from IEC 61241-4:2001.
| Committee |
EL-014
|
| DocumentType |
Standard
|
| ISBN |
0 7337 4382 X
|
| Pages |
19
|
| PublisherName |
Standards Australia
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This part of IEC 61241, gives requirements on the design, construction, testing and marking of electrical apparatus for use in combustible dust atmospheres in which a protective gas (air or inert gas), maintained at a pressure above that of the external atmosphere, is used to prevent the entry of dust which might otherwise lead to the formation of a combustible mixture within enclosures which do not contain a source of combustible dust.This standard contains the specific requirements for construction and testing, including protective requirements that apply to electrical apparatus with type of protection pressurization pD intended for use in potentially combustible dust atmospheres.This standard includes the requirements for the construction of the enclosure and its associated components, including, if any, the inlet and outlet ducts for the protective gas, and for the safety provisions and devices necessary to ensure that pressurization is established and maintained for type of protection pressurization pD.Requirements for pressurized enclosures with an internal source of dust release are not included in this standard.This standard does not cover the requirements for pressurized rooms with or without internal sources of dust release.This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion or to pyrophoric substances.This standard does not cover combined gas and dust hazard. Those requirements are under consideration.The requirements contained in this standard are supplementary to those in IEC 61241.1.1.
| Standards | Relationship |
| IEC 61241-4:2001 | Identical |
First published as AS/NZS 61241.4:2002.
A newer version of this standard is available.