BS 5268-4.2:1990
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Structural use of timber. Fire resistance of timber structures Recommendations for calculating fire resistance of timber stud walls and joisted floor constructions
Hardcopy , PDF
English
30-04-1990
30-03-2010
Foreword
Committees responsible
Recommendations
1 Scope
2 Definitions
3 Fire resistance criteria
4 Materials
5 Construction details
6 Calculation method
Appendix
A Worked examples
Tables
1 Internal walls required to provide a fire resistance
performance of 30:30:30 min. Single leaf walls of
symmetrical/asymmetrical construction exposed to
fire from one side at a time
2 Internal walls required to provide a fire resistance
performance of 60:60:60 min. Single leaf walls of
symmetrical/asymmetrical construction exposed to
fire from one side at a time
3 Internal walls required to provide a fire resistance
performance of 60:60:60 min. Double leaf walls of
symmetrical/asymmetrical construction exposed to
fire from either side
4 External walls required to provide a fire resistance
performance of 30:30:15 min. Single leaf walls of
symmetrical/asymmetrical construction exposed to
fire from the inside only
5 External walls required to provide a fire resistance
performance of 30:30:30 min. Single leaf walls of
symmetrical/asymmetrical construction exposed to
fire from one side
6 External walls required to provide a fire resistance
performance of 60:60:60 min and 60:60:15 min. Single
leaf walls of symmetrical/asymmetrical construction
exposed to fire from one side at a time
7 Specification of materials and conditions of fixings
for walls
8 Timber floors, concealed joists, required to provide
fire resistance performance of 30:15:15 min and
30:30:30 min
9 Timber floors, concealed joists, required to provide
a fire resistance performance of 60:60:60 min
10 Timber floors, exposed joists, required to provide a
fire resistance performance of 30:30:30 min
11 Specification of materials and conditions of fixing
for floors
Figures
1 Diagram showing depth x breadth of stud and breadth
of joist
2 Profiles for tongued and grooved ceiling boards
3 Methods of fixing insulation materials in walls
4 Methods of fixing insulation materials in floors
5 Method of fixing ceiling linings to exposed joists
Extends the code given in Section 4.1 of BS 5268 to include composite timber elements.
| Committee |
B/525/5
|
| DevelopmentNote |
Supersedes 86/14933 DC. (07/2005) Reviewed and confirmed by BSI, November 2007. (10/2007)
|
| DocumentType |
Standard
|
| Pages |
28
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
A newer version of this standard is available.