BS 5660-2:1987
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Methods of sampling iron ores Mechanical method of increment sampling and sample preparation
Hardcopy , PDF
15-07-2001
English
23-12-1987
National foreword
Committees responsible
Method
1 Scope
2 Field of application
3 References
4 Definitions
5 General procedure for sampling and sample
preparation
6 Fundamentals of sampling
7 Method of sampling
8 Method of sample preparation
9 Packing and marking of sample
10 Requirements for mechanical systems
11 Installation for mechanical systems
Annexes
A Equation for number of increments
B Procedure for determining the minimum mass of
divided gross sample for size determination using
other mechanical division methods (for example
mechanical riffle divider)
C Alternative method of taking the reference sample
D Design criteria of primary sampler for avoiding
bias in taking increments
Tables
1 Overall precision, beta SDM (%)
2 Mass of increment
3 Classification of quality variation, sigma w
4 Minimum number of increments required, n1, and
sampling precision, beta s
5 Minimum number of parts per consignment for
moisture determination
6 Examples of minimum mass of divided size gross
sample in other mechanical division methods (for
example mechanically charged riffle divider) and
division precision, beta DM
7 Examples of minimum mass of divided increment or
subsample for size determination in other
mechanical division methods (for example
mechanically charged riffle divider)
8 Minimum mass of divided gross sample for moisture
determination and/or chemical analysis for other
mechanical division methods (for example
mechanically charged riffle divider)
9 Minimum mass of divided individual increment of
subsample for moisture determination and/or
chemical analysis for other mechanical division
methods (for example mechanically charged riffle
divider)
10 Number of test portions for moisture determination
11 Value of sigma w
Figures
1 The precision of sampling for each mass of
consignment
2 Minimum number of increments required
3 An example for constitution of subsample and a
gross sample
4 Sample preparation for chemical analysis
5 An example of sample preparation
6 Examples of diagrammatic illustration for cutter-
type primary samplers
7a) Example of slotted belt type divider
7b) Example of chain bucket type divider
7c) Example of rotary cutter-chute type divider
7d) Example of rotary container type divider
7e) Example of rotary cone type divider
7f) Example of rotary plate type divider
7g) Example of mechanically charged riffle type divider
8 Example of flowsheet for installation
9 Scheme 1
10 Scheme 2
11 Scheme 3
12 Scheme 4
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.