Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 6068-2.86(2003) : 2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

WATER QUALITY - DETERMINATION OF ORTHOPHOSPHATE AND TOTAL PHOSPHORUS CONTENTS BY FLOW ANALYSIS (FIA AND CFA) - PART 1: METHOD BY FLOW INJECTION ANALYSIS (FIA)

Published date

23-11-2012

Superseded date

07-02-2005

Superseded by

BS EN ISO 15681-1:2004

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Interferences
   3.1 General interferences
   3.2 Interferences in the determination of total-P
4 Principle
   4.1 Determination of orthophosphate
   4.2 Total phosphorus with manual digestion
5 Reagents
6 Apparatus
   6.1 Flow injection analysis (FIA)
   6.2 Additional apparatus
   6.3 Additional apparatus for the determination of total
       phosphorus
7 Sampling and sample preparation
8 Procedure
   8.1 Analysis preparation
   8.2 Instrument performance check
   8.3 Reagent blank check
   8.4 Calibration
   8.5 Check of digestion efficiency for determination of
       total-P
   8.6 Measurement
   8.7 Closing down the system
9 Calculation of results
10 Expression of results
11 Test report
Annex A (informative) Example of an FIA system
Annex B (informative) Precision and accuracy
Annex C (informative) Determination of orthophosphate-P
                      and total-P by FIA using ascorbic
                      acid reduction
Annex D (informative) Replacement of hydrazine sulfate by
                      DEHA (N,N-diethylhydroxylamine)
Bibliography

Specifies flow injection analysis (FIA) methods for the determination of orthophosphate in the mass concentration range from 0,01 mg/l to 1,0 mg/l (P), and total phosphorus by manual digestion in accordance with ISO 6878 [5], [6] for the mass concentration range from 0,1 mg/l to 10 mg/l (P).

Committee
EH/3/2
DevelopmentNote
Also numbered as BS ISO 15681-1. (02/2004) Supersedes 01/562317 DC. (02/2005)
DocumentType
Standard
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
ISO 15681-1:2003 Identical

ISO 5667-2:1991 Water quality — Sampling — Part 2: Guidance on sampling techniques
ISO 15681-2:2003 Water quality — Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) — Part 2: Method by continuous flow analysis (CFA)
ISO 5667-3:2012 Water quality — Sampling — Part 3: Preservation and handling of water samples
ISO 5667-1:2006 Water quality — Sampling — Part 1: Guidance on the design of sampling programmes and sampling techniques
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
ISO 8466-1:1990 Water quality — Calibration and evaluation of analytical methods and estimation of performance characteristics — Part 1: Statistical evaluation of the linear calibration function
ISO 6878:2004 Water quality — Determination of phosphorus — Ammonium molybdate spectrometric method

Sorry this product is not available in your region.