Foreword
Method
1 Scope
2 Principle
3 Reagents
4 Apparatus
5 Sampling
6 Procedure
7 Calculation and expression of results
8 Test report

Gives a volumetric method for determining copper in permanent magnet alloys. Applicable to the determination of copper in permanent magnet alloys containing 5% to 15% aluminium, 7% to 35% nickel, 10% to 30% cobalt, 0.5% to 8% copper, up to 3% titanium, up to 6% niobium and the remainder iron.

Committee
ISE/1
DevelopmentNote
Supersedes 85/36504 DC (09/2005) Reviewed and confirmed by BSI, November 2008. (11/2008)
DocumentType
Standard
Pages
8
PublisherName
British Standards Institution
Status
Current

This Subsection of BS 6200 describes a volumetric method for the determination of copper in permanent magnet alloys.

The method is applicable to the determination of copper in permanent magnet alloys containing 5 % m/m to 15 % m/m aluminium, 7 % m/m to 35 % m/m nickel, 10 % m/m to 30 % m/m cobalt, 0.5 % m/m to 8 % m/m copper, up to 3 % m/m titanium, up to 6 % m/m niobium and the remainder iron.

NOTE The titles of the publications referred to in this Subsection of BS 6200 are listed on the inside back cover.

BS 6200-1:1991 Sampling and analysis of iron, steel and other ferrous metals Introduction and contents
BS 1837:1970 Methods for the sampling of iron, steel, permanent magnet alloys and ferro-alloys
BS 846:1985 Specification for burettes

$325.41
Including GST where applicable