Specification for installation of gas-fired hot water boilers of rated inputs between 60 kW and 2 MW (2nd and 3rd family gases)

Available format(s)

Hardcopy

Language(s)

English

Published date

31-03-1986

Superseded date

31-07-1990

Superseded by

BS 6644:1990

$531.66
Including GST where applicable

Committee
GSE/30
DocumentType
Standard
Pages
0
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 6880-1:1988 Code of practice for low temperature hot water heating systems of output greater than 45 kW Fundamental and design considerations
BS 5978-1:1989 Safety and performance of gas-fired hot water boilers (60 kW to 2 MW input) Specification for general requirements
BS 6880-2:1988 Code of practice for low temperature hot water heating systems of output greater than 45 kW Selection of equipment
BS 6880-3:1988 Code of practice for low temperature hot water heating systems of output greater than 45 kW Installation, commissioning and maintenance

BS 1179-6:1980 Glossary of terms used in the gas industry Combustion and utilization including installation at consumers\' premises
BS 5978-1:1983 Safety and performance of gas-fired hot water boilers (60kW to 2 MW input) Specification for general requirements
BS CP99(1972) : LATEST FROST PRECAUTIONS FOR WATER SERVICES
BS 2871-1:1971 Specification for copper and copper alloys. Tubes Copper tubes for water, gas and sanitation
BS 3554-1:1971 Specification for gas governors Independent governors for inlet pressures up to 25 mbar
BS 5978-2:1983 Safety and performance of gas-fired hot water boilers (60 kW to 2 MW input). Specification for additional requirements for boilers with atmospheric burners
BS 6759-1:1984 Safety valves Specification for safety valves for steam and hot water
BS 5258-1:SUPP1(1983) : LATEST SAFETY OF DOMESTIC GAS APPLIANCES - FAN-POWERED APPLIANCES
BS 2871-2:1972 Specification for copper and copper alloys. Tubes Tubes for general purposes
BS 5978-3:1983 Safety and performance of gas-fired hot water boilers (60kW to 2 MW input) Specification for additional requirements for boilers with forced or induced draught burners
BS 759-2:1975 Valves, gauges and other safety fittings for application to boilers and to piping installations for and in connection with boilers. Specification for safety valves
BS 2871-3:1972 Specification for copper and copper alloys. Tubes Tubes for heat exchangers
BS CP3:CH4-3(1968) : LATEST CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - PRECAUTIONS AGAINST FIRE - OFFICE BUILDINGS
BS 3554-2:1972 Specification for gas governors Independent governors for inlet pressures up to 350 mbar