Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

BS EN 1364-1:2015

Current

Current

The latest, up-to-date edition.

Fire resistance tests for non-loadbearing elements Walls

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-07-2015

$701.25
Including GST where applicable
Summarise this standard

European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (normative) - Specific requirements for testing
        glazed elements or non-loadbearing walls
        incorporating glazing
Annex B (normative) - Specific requirements for testing
        non-loadbearing external and internal walls designed
        to span horizontally between two independently
        proven fire resisting vertical structural elements
Bibliography

Describes a method for determining the fire resistance of non-loadbearing walls.

Committee
FSH/22/-/7
DevelopmentNote
Supersedes 94/303844 DC. (09/2005) Supersedes 11/30252238 DC. (07/2015)
DocumentType
Standard
Pages
50
PublisherName
British Standards Institution
Status
Current
Supersedes

This European standard specifies a method for determining the fire resistance of non-loadbearing walls. This European Standard is used in conjunction with EN1363‑1 . It is applicable to internal non-loadbearing walls (partitions), with and without glazing, non-loadbearing walls consisting almost wholly of glazing (glazed non-loadbearing walls) and other non-loadbearing internal and external non-loadbearing walls with and without glazing. The fire resistance of external non-loadbearing walls can be determined under internal or external exposure conditions. In the latter case the external fire exposure curve given in EN1363‑2 is used. It is not applicable to: curtain walls (external non-loadbearing walls suspended in front of the floor slab), unless explicitly permitted under EN1364‑3 or EN1364‑4 which contain details of the methodology to be used. non-loadbearing walls containing door assemblies that are tested according to EN1634‑1 . Specific requirements for testing glazed elements or non-loadbearing walls incorporating glazing are given in AnnexA. Specific requirements relating to the testing of non-loadbearing external and internal walls designed to span horizontally between two independently proven fire resisting vertical structural elements are given in AnnexB.

Standards Relationship
EN 1364-1:2015 Identical
EN 1364-1:1999 Identical
I.S. EN 1364-1:2015 Identical
NBN EN 1364-1 : 2015 Identical
NEN EN 1364-1 : 2015 Identical
NS EN 1364-1 : 1999 Identical
NF EN 1364-1 : 2015 Identical
DIN EN 1364-1:2015-09 Equivalent
UNE-EN 1364-1:2000 Identical
EN 1364-1:2015 Equivalent

$701.25