BS EN 14647:2005
Current
The latest, up-to-date edition.
Calcium aluminate cement. Composition, specifications and conformity criteria
Hardcopy , PDF
English
28-02-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Calcium aluminate cement (CAC)
5 Constituents
5.1 Calcium aluminate cement clinker
5.2 Grinding aids
6 Cement type and composition
7 Mechanical, physical and chemical requirements
7.1 Compressive strength
7.2 Initial setting time
7.3 Chemical requirements
8 Standard designation
9 Conformity criteria
9.1 General requirements
9.2 Conformity criteria and evaluation procedure
Annex A (informative) Guidance for the use of calcium
aluminate cement in concrete and
mortar
A.1 Introduction
A.2 Specific characteristics of calcium aluminate
cement
A.3 Hydraulic properties
A.4 Production of calcium aluminate cement concrete
A.5 Admixtures
A.6 Use of calcium aluminate cement in
particular conditions
A.7 Rapid test to estimate the minimum long term
strength of calcium aluminium cement concretes
A.8 Bibliography
Annex B (informative) Water-soluble hexavalent chromium
Annex ZA (informative) Clauses of this European Standard
addressing the provisions of
EU Construction Products Directive
ZA.1 Scope and relevant characteristics
ZA.2 Procedure for the attestation of conformity
of products
ZA.3 CE marking and labelling
Bibliography
Provides a general definition of calcium aluminate cement and its composition.
| Committee |
B/516/6
|
| DevelopmentNote |
Supersedes BS 915-2(1972). (02/2006) Supersedes 03/303925 DC. (03/2006)
|
| DocumentType |
Standard
|
| Pages |
38
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This European Standard gives a general definition of calcium aluminate cement and its composition. It includes requirements for the mechanical, physical and chemical properties and also states the conformity criteria and the related rules.
Calcium aluminate cement used as a constituent material of formulated mixes for specific applications (e.g. dry mixes) is outside the scope of this European Standard.
NOTE Guidance for the correct use of calcium aluminate cement in concrete and mortars is given in Annex A.
| Standards | Relationship |
| EN 14647:2005 | Identical |
| NF EN 14647 : 2006 | Identical |
| DIN EN 14647:2006-01 | Identical |
| NBN EN 14647 : 2006 COR 2006 | Identical |
| NEN EN 14647 : 2005 C1 2007 | Identical |
| NS EN 14647 : 2005 AC 2006 | Identical |
| I.S. EN 14647:2005 | Identical |
| EN 14647:2005/AC:2006 | Identical |
| UNE-EN 14647:2005 | Equivalent |
| EN 14647:2005 | Equivalent |
| UNE-EN 14647:2006 | Identical |
| I.S. EN 14647:2005 | Equivalent |