Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 16215:2020

Current

Current

The latest, up-to-date edition.

Animal feeding stuffs: Methods of sampling and analysis. Determination of dioxins and dioxin-like PCBs by GC/HRMS and of indicator PCBs by GC/HRMS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

20-01-2020

$737.91
Including GST where applicable

This document is applicable to the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), (together termed ‘dioxins’ (PCDD/Fs)) and dioxin-like PCBs and non-dioxin-like PCBs (dl-PCBs and ndl-PCBs) in animal feeding stuffs.

Committee
AW/10
DocumentType
Standard
ISBN
9780539002799
Pages
58
PublisherName
British Standards Institution
Status
Current
Supersedes

This document is applicable to the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), (together termed ‘dioxins’ (PCDD/Fs)) and dioxin-like PCBs and non-dioxin-like PCBs (dl-PCBs and ndl-PCBs) in animal feeding stuffs. Collaborative studies have been carried out. The method is suitable for the determination of dioxins, dl-PCBs and ndl-PCBs at the appropriate MRL in compound feed and ingredients e.g. oil, mineral clay. The method is applicable to samples containing trace level amounts of one or more dioxins, dioxin-like PCBs and non-dioxin-likePCBs. The limit of quantification (LOQ) is 0,05pg/g (OCDD/ F=0,1pg/g) for the relevant individual congeners of dioxins/furans, 0,05pg/g for non-ortho PCBs, 10pg/g for mono-ortho PCBs, and 100pg/g for non-dioxin-like-PCBs. For determination of dioxins and dioxin-like PCBs, the procedure can be used as confirmatory method as defined by Commission Regulation (EC) No 152/2009 for dioxins and dl-PCB in feed [1]. Confirmatory methods as described in this standard are high-resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) methods. If only the analysis of non-dioxin-like PCBs is required, a GC-LRMS method can be used (e.g. EN 15741 [2]) provided that appropriate analytical performance criteria are met in the relevant range for the matrix of interest.This document is split into four modules. Each module describes a part of the whole procedure (see Figure1 and Figure2) to be followed: Module A: Description of standards which might be used; Module B: Description of extraction procedures; Module C: Description of clean-up procedures; Module D: GC/HRMS determination. Each module describes a part of the whole method as well as, when applicable, alternatives which should be equivalent. Each module has to be regarded as an example. Combining modules and/or alternatives gives a highly flexible, “performance based” procedure. It is permitted to modify the method if all performance criteria laid down in CommissionRegulation(EC)No152/2009 [1] are met.Any deviation of the described method, combination of modules needs to be recorded as part of the QA/QC procedures of accredited laboratories and should be available on request.

Standards Relationship
EN 16215:2020 Identical
DIN EN 16215:2020-05 Equivalent
I.S. EN 16215:2020 Equivalent
UNE-EN 16215:2020 Equivalent

$737.91
Including GST where applicable