Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (normative) - Conditioning requirements
Annex B (normative) - Field of direct application limits
        of permitted size variations
Annex C (informative) - Background to field of direct
        application statements for asymmetric
        constructions and supporting constructions
Bibliography

Defines a method for determining the fire resistance of door and shutter assemblies and openable windows designed for installation within openings incorporated in vertical separating elements, such as: a) hinged and pivoted doors; b) horizontally sliding and vertically sliding doors including articulated sliding doors and sectional doors; c) folding doors, sliding folding doors/shutters; d) tilting doors; e) rolling shutter doors; f) openable windows; g) operable fabric curtains.

Committee
FSH/22/-/5
DevelopmentNote
Supersedes 94/307751 DC. (12/2002)
DocumentType
Standard
Pages
158
PublisherName
British Standards Institution
Status
Current
Supersedes

12/30263295 DC : 0 BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION
13/30277228 DC : 0 BS 8607 - MECHANICALLY OPERATED PUSH-BUTTON LOCKSETS - REQUIREMENTS AND TEST METHODS
16/30332500 DC : 0 BS 8214 - TIMBER-BASED FIRE DOOR ASSEMBLIES - CODE OF PRACTICE
BS 8524-1:2013 Active fire curtain barrier assemblies Specification
09/30189801 DC : 0 BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION
BS DD9999(2005) : 2005 CODE OF PRACTICE FOR FIRE SAFETY IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS
BS 8214:2016 Timber-based fire door assemblies. Code of practice
BS 8214:2008 Code of practice for fire door assemblies
BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings
BS 9991:2015 Fire safety in the design, management and use of residential buildings. Code of practice
BS 8607(2014) : 2014 MECHANICALLY OPERATED PUSH BUTTON LOCKSETS - REQUIREMENTS AND TEST METHODS
07/19977411 DC : DRAFT FEB 2007 BS 8214 - CODE OF PRACTICE FOR FIRE DOOR ASSEMBLIES
07/30147204 DC : 0 BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS
04/30104952 DC : DRAFT MARCH 2004 BS 5502-23 - BUILDING AND STRUCTURES FOR AGRICULTURE - PART 23 - FIRE PRECAUTIONS - CODE OF PRACTICE
PD 7974-3:2011 Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin
BS 476-10:2009 Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs
BS 8524-2:2013 Active fire curtain barrier assemblies Code of practice for application, installation and maintenance
BS 9991:2011 Fire safety in the design, management and use of residential buildings. Code of practice
11/30203947 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
BS 5516-2:2004 Patent glazing and sloping glazing for buildings Code of practice for sloping glazing
12/30205676 DC : 0 BS 8524-2 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 2: CODE OF PRACTICE
04/30100932 DC : DRAFT AUG 2004 BS 6510 - STEEL-FRAMED WINDOWS AND GLAZED DOORS
BS 8424:2004 Building hardware. Pull handles. Requirements and test methods
PD 7974-3:2003 Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin (Sub-system 3)
BS PAS 121(2007) : 2007 SPECIFICATION FOR ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES AND ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WITH SMOKE RATING

ISO 13943:2017 Fire safety — Vocabulary
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
PREN 16034 : DRAFT 2009 PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS
EN 1634-2:2008 Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware
EN 12519:2004 Windows and pedestrian doors - Terminology
EN 1366-7:2004 Fire resistance tests for service installations - Part 7: Conveyor systems and their closures
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 1366-2:2015 Fire resistance tests for service installations - Part 2: Fire dampers
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
EN 14600:2005 Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification

$641.66
Including GST where applicable