Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

BS EN 60079-15:2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Explosive atmospheres Equipment protection by type of protection \'n\'

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-11-2016

Superseded date

11-05-2019

$797.50
Including GST where applicable
Summarise this standard

1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Temperatures
6 Requirements for electrical equipment
7 Connection facilities and terminal compartments
8 Supplementary requirements for non-sparking
   electrical machines
9 Supplementary requirements for non-sparking fuses
   and fuse assemblies
10 Supplementary requirements for non-sparking plugs
   and sockets
11 Supplementary requirements for non-sparking luminaires
12 Supplementary requirements for equipment incorporating
   non-sparking cells and batteries
13 Supplementary requirements for non-sparking low power
   equipment
14 Supplementary requirements for non-sparking current
   transformers
15 Other non-sparking electrical equipment
16 General supplementary requirements for equipment producing
   arcs, sparks or hot surfaces
17 Supplementary requirements for enclosed-break devices
   and non-incendive components producing arcs, sparks or
   hot surfaces
18 Supplementary requirements for hermetically sealed
   devices producing arcs, sparks or hot surfaces
19 Supplementary requirements for sealed devices producing
   arcs, sparks or hot surfaces
20 Supplementary requirements for restricted-breathing
   enclosures protecting equipment producing arcs, sparks
   or hot surfaces
21 General information on verification and tests
22 Type tests
23 Routine verifications and tests
24 Marking
25 Documentation
26 Instructions
Annex A (informative) - Application, installation, and testing
        considerations for Ex 'nA' asynchronous machines
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications
Annex ZY (informative) - Significant changes between this
         European Standard and EN 60079-15:2005
Annex ZZ (informative) - Coverage of essential requirements
          of the directive 94/9/EC
National Annex NA (informative) - IEC 60079-15
         Edition 4.0 2010-01

Defines requirements for the construction, testing and marking for Group II electrical equipment with type of protection, 'n' intended for use in explosive gas atmospheres.

Committee
EXL/31
DevelopmentNote
To be read in conjunction with BS EN 60079-0. Supersedes 96/214727 DC (10/2003) Supersedes DD ENV 50269. (04/2005) Supersedes BS 6941(1988). (11/2005) 2003 version has been declared inactive for the new design. Supersedes BS EN 50021. (05/2008) Supersedes 07/30168628 DC & 08/30186575 DC. (09/2010)
DocumentType
Standard
ISBN
9780580962271
Pages
84
ProductNote
Implementation of IEC Interpretation Sheet 1 September 2016 in National Annex NA(30-11-2016)
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of IEC60079 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection, \'n\' intended for use in explosive gas atmospheres. This standard applies to electrical equipment where the rated voltage does not exceed 15kV r.m.s. a.c. or d.c. This part of IEC60079 is applicable to non-sparking electrical equipment and also to electrical equipment with parts or circuits producing arcs or sparks or having hot surfaces which, if not protected in one of the ways specified in this standard, could be capable of igniting a surrounding explosive gas atmosphere. This standard describes several different methods by which this can be achieved which may be combined with other methods described in IEC60079‑0 . This standard supplements and modifies the general requirements of IEC60079‑0 , except as indicated in Table1. Where a requirement of this standard conflicts with a requirement of IEC60079‑0 , the requirement of this standard takes precedence. Table1 Relationship of this part to IEC60079-0 Clause of IEC60079‑0 IEC60079‑0 clause application to IEC60079‑15 Ed. 5.0 (2007) (informative) Ed. 6.0 1 (future edition) (informative) Clause / Subclause title (normative) Protected spar king Non sparking Restricted breathing nC nA nR 4 4 Equipment grouping Applies Applies Applies 4.1 4.1 Group I Excluded Excluded Excluded 4.2 4.2 Group II Applies Applies Applies 4.3 4.3 Group III Excluded Excluded Excluded 4.4 4.4 Equipment for a particular explosive atmosphere Applies Applies Applies 5.1 5.1 Environmental influences Applies Applies Applies 5.1.1 5.1.1 Ambient temperature Applies Applies Applies 5.1.2 5.1.2 External source of heating or cooling Applies Applies Applies 5.2 5.2 Service temperature Applies Applies Applies 5.3.1 5.3.1 Determination of maximum surface temperature Applies Applies Applies 5.3.2.1 5.3.2.1 Group I electrical equipment Excluded Excluded Excluded 5.3.2.2 5.3.2.2 Group II electrical equipment Applies Applies Applies 5.3.2.3 5.3.2.3 Group III electrical equipment Excluded Excluded Excluded 5.3.3 5.3.3 Small component temperature for Group I and Group II electrical equipment Applies Applies Excluded 6.1 6.1 General Applies Applies Applies 6.2 6.2 Mechanical strength Applies Applies Applies 6.3 6.3 Opening times Excluded Excluded Applies 6.4 6.4 Circulating currents Applies Applies Applies 6.5 6.5 Gasket retention Applies Applies Applies 6.6 6.6 Electromagnetic and ultrasonic radiating equipment Applies Applies Applies 7.1.1 7.1.1 Applicability Applies Applies Applies 7.1.2 7.1.2 Specification of materials Applies Applies Applies 7.1.3 7.1.2.2 Plastic materials Applies Applies Applies 7.1.4 7.1.2.3 Elastomeric materials Applies Applies Applies 7.2 7.2 Thermal endurance Applies Applies Applies 7.3 7.3 Resistance to light Applies Applies Applies 7.4 7.4 Electrostatic charges on external non-metallic materials Applies Applies Applies 7.5 9.1 Threaded holes Applies Applies Applies 8.1.1 8.2 Group I Excluded Excluded Excluded 8.1.2 8.3 Group II Applies Applies Applies 8.1.3 8.4 Group III Excluded Excluded Excluded 8.2 9.1 Threaded holes Applies Applies Applies 9.1 9.1 General Applies Applies Applies 9.2 9.2 Special fasteners Excluded Excluded Excluded 9.3 9.3 Holes for special fasteners Excluded Excluded Excluded 10 10 Interlocking devices Excluded Excluded Excluded 11 11 Bushings Applies Applies Applies 12 12 Materials used for cementing Modified Modified Modified 13 13 Ex components Applies Applies Applies 14 14 Connection facilities and termination compartments Modified Modified Modified 15 15 Connection facilities for earthing and bonding conductors Applies Applies Applies 16 16 Entries into enclosures Applies Applies Applies 17 17 Supplementary requirements for rotating electrical machines Excluded Modified Excluded 18 18 Supplementary requirements for switchgear Applies Applies Applies 19 19 Supplementary requirements for fuses Modified Modified Modified 20 20 Supplementary requirements for plugs and sockets Modified Modified Modified 21 21 Supplementary requirements for luminaires Modified Modified Modified 22 22 Supplementary requirements for caplights and handlights Applies Applies Applies 23 23 Equipment incorporating cells and batteries Modified Modified Modified 24 24 Documentation Applies Applies Applies 25 25 Compliance of prototype or sample with documents Applies Applies Applies 26.1 26.1 General Applies Applies Applies 26.2 26.2 Test configuration Applies Applies Applies 26.3 26.3 Tests in explosive test mixtures Applies Applies Applies 26.4 26.4 Tests of enclosures Applies Applies Applies 26.4.1.1 26.4.1.1 Metallic enclosures, metallic parts of enclosures and glass parts of enclosures Applies Applies Applies 26.4.1.2.1 26.4.1.2.1 Group I electrical equipment Excluded Excluded Excluded 26.4.1.2.2 26.4.1.2.2 Group II and Group III electrical equipment Applies Applies Applies 26.4.2 26.4.2 Resistance to impact Applies Applies Applies 26.4.3 26.4.3 Drop test Applies Applies Applies 26.4.4 26.4.4 Acceptance criteria Applies Applies Applies 26.4.5 26.4.5 Degree of protection by enclosure Applies Applies Applies 26.5 26.5 Thermal tests Applies Applies Applies 26.6 26.6 Torque test for bushings Applies Applies Applies 26.7 26.7 Non-metallic enclosures or non-metallic parts of enclosures Modified Modified Modified 26.8 26.8 Thermal endurance to heat Modified Modified Modified 26.9 26.9 Thermal endurance to cold Applies Applies Applies 26.10 26.10 Resistance to light Applies Applies Applies 26.11 26.11 Resistance to chemical agents for Group I electrical equipment Excluded Excluded Excluded 26.12 26.12 Earth continuity Applies Applies Applies 26.13 26.13 Surface resistance test of parts of enclosures of non-metallic materials Applies Applies Applies 26.14 - Charging tests Applies Applies Applies 26.15 26.14 Measurement of capacitance Applies Applies Applies 27 27 Routine tests Applies Applies Applies 28 28 Manufacturers responsibility Applies Applies Applies 29 29 Marking Applies Applies Applies 30 30 Instructions Applies Applies Applies AnnexA AnnexA Supplementary requirements for Ex cable glands Applies Applies Applies AnnexB AnnexB Requirements for Ex components Applies Applies Applies AnnexC AnnexC Example of rig for resistance to impact test Applies Applies Applies AnnexD AnnexD Introduction to an alternative risk assessment method encompassing “equipment protection levels” fro Ex equipment Applies Applies Applies Applies : this requirement of IEC60079‑0 is applied without change. Excluded : this requirement of IEC60079‑0 does not apply. Modified : this requirement of IEC60079‑0 is modified as detailed in this standard. NOTE1 The clause number in the above table is shown for information only. The applicable requirements of IEC60079‑0 are identified by the clause title which is normative. This document was written against the specific requirements of IEC60079‑0 (ed. 5.0). The clause numbers for the previous edition are shown for information only. This is to enable the General Requirements IEC60079‑0 (ed. 5.0) to be used where necessary with this part of IEC60079 . Where there were no requirements, indicated by “NR” or there is a conflict between requirements, the later edition requirements take precedence. NOTE2 A non-incendive component is limited in use to the particular circuit for which it has been shown to be non-ignition capable and, therefore, cannot be separately assessed as complying with this standard. NOTE3 Compliance with this standard does not imply any removal of, or lowering of the requirements of any other standard with which the electrical equipment complies. NOTE4 This part of IEC60079 supplements, and may enhance, the requirements for equipment for normal industrial applications. Where compliance with other IEC standards is indicated, such as IEC60034 for motors and IEC60598‑2 for luminaires, proving compliance to those standards is normally the responsibility of the manufacturer. NOTE5 Type of protection “n” provides Equipment Protection Level (EPL) Gc. For further information, see IEC60079‑0 .

Standards Relationship
I.S. EN 60079-15:2010 Identical
NF EN 60079-15 : 2010 Identical
EN 60079-15:2010 Identical
DIN EN 60079-15 : 2011 Identical
IEC 60079-15:2010 Identical
NBN EN 60079-15 : 2010 Identical
IEC 60079-15:2010/ISH1:2016 Identical
UNE-EN 60079-15:2013 Identical
UNE-EN 60079-15:2010 Equivalent

⚠

A newer version of this standard is available.

View Current Edition View Current Edition View Current Edition
$797.50
Including GST where applicable