BS EN 60099-8:2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Surge arresters Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-06-2011

Superseded date

30-04-2018

Superseded by

BS EN IEC 60099-8:2018

$737.91
Including GST where applicable
Summarise this standard

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Identification and classification
5 Standard ratings and service conditions
6 Requirements
7 General testing procedure
8 Type tests
9 Routine tests
10 Acceptance tests
Annex A (informative) - Example of a test circuit
        for the follow current interrupting test
Annex B (normative) - Mechanical considerations
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Describes surge arresters to protect the insulator assembly from lightning-caused overvoltages only.

Committee
PEL/37
DevelopmentNote
Supersedes 09/30167595 DC. (07/2011)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of IEC 60099 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers.

This standard defines surge arresters to protect the insulator assembly from lightning-caused overvoltages only. Therefore, and since the metal-oxide resistors are not permanently connected to the line, the following items are not considered for this standard:

  • switching impulse sparkover voltage;

  • residual voltage at steep current and switching current impulse;

  • thermal stability;

  • long-duration current impulse withstand duty;

  • power-frequency voltage versus time characteristics of an arrester;

  • disconnector test;

  • aging duties by power-frequency voltage.

Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc.

Designs with the EGLA\'s external series gap installed in parallel to an insulator are not covered by this standard.

Standards Relationship
IEC 60099-8:2017 Identical
I.S. EN 60099-8:2011 Equivalent
EN 60384-14-2:2004 Identical
EN 60099-8:2011 Identical
IEC 60099-8:2011 Identical
IEC 60384-14-2:2004 Identical
UNE-EN 60099-8:2011 Equivalent
EN 60099-8:2011 Equivalent

⚠

A newer version of this standard is available.

View Current Edition
$737.91
Including GST where applicable