BS EN 60143-1:2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Series capacitors for power systems General
Hardcopy , PDF
English
31-10-2015
09-01-2024
| Committee |
W/-
|
| DevelopmentNote |
Renumbers and supersedes BS EN 60143. Supersedes 91/29696 DC. 1993 version incorporates amendment 8725 to BS EN 60143. (09/2005) Supersedes 01/203455 DC (10/2005) Supersedes 14/30310457 DC. (10/2015)
|
| DocumentType |
Standard
|
| Pages |
70
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| Supersedes |
This part of IEC60143 applies both to capacitor units and capacitor banks intended to be used connected in series with an a.c. transmission or distribution line or circuit forming part of an a.c. power system having a frequency of 15Hz to 60Hz. The primary focus of this standard is on transmission application. The series capacitor units and banks are usually intended for high-voltage power systems. This standard is applicable to the complete voltage range. This standard does not apply to capacitors of the self-healing metallized dielectric type. The following capacitors, even if connected in series with a circuit, are excluded from this standard: capacitors for inductive heat-generating plants ( IEC60110‑1 ); capacitors for motor applications and the like ( IEC60252(all parts)); capacitors to be used in power electronics circuits ( IEC61071 ); capacitors for discharge lamps ( IEC61048 and IEC61049 ). For standard types of accessories such as insulators, switches, instrument transformers, external fuses, etc. see the pertinent IEC standard. NOTE1 Additional requirements for capacitors to be protected by internal fuses, as well as the requirements for internal fuses, are found in IEC60143‑3 . See also AnnexC. NOTE2 Additional requirements for capacitors to be protected by external fuses, as well as the requirements for external fuses, are found in AnnexA and AnnexC. NOTE3 A separate standard for series capacitor accessories (spark-gaps, varistors, discharge reactors, current-limiting damping reactors, damping resistors, circuit-breakers, etc.), IEC60143‑2, has been revised and was completed in 2012. A separate standard for internal fuses for series capacitors, IEC60143‑3 has been revised and was completed in 2013. NOTE4 Some information regarding fuseless capacitor units and fuseless capacitor banks is found in AnnexC. The object of this standard is: to formulate uniform rules regarding performance, testing and rating; to formulate specific safety rules; to serve as a guide for installation and operation.
| Standards | Relationship |
| EN 50525-2-83:2011 | Identical |
| EN 60143-1:2015 | Identical |
| IEC 60143-1:2015 | Identical |
| NBN EN 60143-1 : 2005 | Identical |
| DIN EN 60143-1 : 2016 | Identical |
| I.S. EN 60143-1:2015 | Identical |
| NF EN 60143-1 : 2015 | Identical |
| UNE-EN 60143-1:2015 | Equivalent |
| UNE-EN 60143-1:2004 | Identical |
| EN 60143-1:2015 | Equivalent |
This standard has been withdrawn and is no longer current. No replacement edition is available.