BS EN 60269-2:1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

24-09-2002

Superseded date

29-06-2007

$325.41
Including GST where applicable

Committees responsible
National foreword
Foreword
1 General
    1.1 Scope
    1.2 Object
4 Classification
5 Characteristics of fuses
         5.3.2 Rated currents of the fuse-holder
    5.5 Rated power dissipation of a fuse-link
         and rated power acceptance of a fuse-holder
    5.6 Limits of time-current characteristics
         5.7.2 Rated breaking capacity
6 Marking
    6.1 Markings of the fuse-holders
    6.2 Markings of the fuse-links
    7.2 Insulating properties
    7.6 Cut-off current characteristics
    7.7 I2t characteristics
8 Tests
         8.4.3.3 Verification of time-current
                 characteristics and gates
         8.9.1 Verification of resistance to heat
                 of the fuse-holder
         8.11.1 Mechanical strength
Figure 1 - Time-current zone 'aM'
Table A - Gates for 'aM' fuse-links (all rated currents)
Table B - Minimum rated breaking capacities
Table C - Maximum operating I2t values for 'aM' fuse-links
Table D - Cross-sectional areas of copper conductors for the
           test of 'aM' fuse-links

Requirements supplementary to those of Part 1 for fuses generally intended to be used in installations where the fuse-links are accessible to authorized persons only.

Committee
PEL/32
DevelopmentNote
Renumbers and supersedes BS 88-2.1(1988). 1995 version incorporates amendment 8741 to BS 88-2.1(1988). Supersedes BS 88-2(1975), 00/201931 DC and 79/21092 DC. (10/2005).
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 7430:1998 Code of practice for earthing
BS 3535-1(1996) : 1996 ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS
BS EN 60269-3:1995 BS Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications)
BS 88-3.1(1995) : 1995 LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS)
BS EN 60742:1996 Isolating transformers and safety isolating transformers. Requirements
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
EN 60742:1995 Isolating transformers and safety isolating transformers - Requirements

IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 60269-2-1:2004 Low-voltage fuses - Part 2-1: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)

$325.41