Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 60444-1:1997

Current

Current

The latest, up-to-date edition.

Measurement of quartz crystal unit parameters Basic method for the measurement of resonance frequency and resonance resistance of quartz crystal units by zero phase technique in a π-network

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-08-2000

$531.66
Including GST where applicable

Committees responsible
National foreword
Foreword
1 Scope
2 Definition of resonance frequency
3 Reference plane and shielding box
4 Principle of measurement
5 Measuring circuit
      5.1 The p-network
      5.2 Accessories of the p-network
      5.3 Associated equipment
6 Method of measurement
      6.1 Initial calibration of the p-network
      6.2 Frequency and resistance measurement
Appendix A - Additional information on accuracy
Annex B (normative) updating of some formulae of Appendix A
Figure 1
Figure 2
Figure 3 - Plot showing the phase change from the value at
           25 O versus reference resistor values from 0 to
           100 O AT 10 MHz, 50 MHz, 100 MHz and 200 MHz.
           Measuring circuit according to, Figure 1 page 4
Figure 4 - Reference resistors and shorting blank
Figure 5a
Figure 5a
Figure A.1
Figure A.2
Figure A.3
Figure A.4
Figure A.5
Figure A.6
Figure A.7
Figure A.8 - A typical phase/frequency variation of an
             adjusted p-network with a 25 O reference
             resistor
Figure A.9 - Typical p-network
Figure A.10 - Detail of network assembly
Figure A.11 - Dimensions of contacting plates and earthed
              shield; x indicates position of rod and disk
              centers of p-network
Figure A.12 - Position of the reference resistor with
              respect to the network contacting plates
Figure A.13 - Other design of a p-network

Defines a simple method for measuring resonance frequency and resonance resistance of quartz crystal units, and establishes a suitable measuring network.

Committee
W/-
DevelopmentNote
Renumbers and supersedes BS 7681-1(1993). 1997 version incorporates amendment 9657 to BS 7681-1(1993). Also numbered as IEC 60444-1. Supersedes 97/202227 DC. (04/2005)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Current
Supersedes

BS EN 60444-2:1997 Measurement of quartz crystal unit parameters Phase offset method for measurement of motional capacitance of quartz crystal units
BS EN 60444-4:1997 Measurement of quartz crystal unit parameters Method for the measurement of the load resonance frequency <i>f</i><sub>L</sub>, load resonance resistance <i>R</i><sub>L</sub> and the calculation of other derived values of quartz crystal units, up to 30 MHz

$531.66
Including GST where applicable