BS EN 60806:2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Determination of the maximum symmetrical radiation field from a rotating anode X-ray tube for medical diagnosis

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-08-2006

Superseded date

20-01-2023

Superseded by

BS EN IEC 60806:2022

$325.41
Including GST where applicable

INTRODUCTION
1 Scope and object
  1.1 Scope
  1.2 Object
2 Terminology
  2.1 Degree of requirements
  2.2 Definitions
3 Other international standards
4 Maximum symmetrical RADIATION FIELD
  4.1 Orientation of the maximum symmetrical RADIATION
      FIELD
  4.2 Distribution of AIR KERMA RATE
  4.3 Maximum AIR KERMA RATE
5 Measurement of the distribution of AIR KERMA RATE
  5.1 Measuring arrangement
  5.2 Measuring conditions
6 Compliance
  6.1 Assessment of compliance
  6.2 Statement of compliance
APPENDIX A - Index of terms
APPENDIX B - Determination of AIR KERMA RATE by radiographic
             densitometric measurement

Applies to X-RAY SOURCE ASSEMBLIES and X-RAY TUBE ASSEMBLIES containing ROTATING ANODE X-RAY TUBES, for use in MEDICAL DIAGNOSTIC RADIOLOGY for techniques in which the X-RAY PATTERN will be received simultaneously in all points of the IMAGE RECEPTION AREA.

Committee
CH/62/2
DevelopmentNote
Supersedes BS 6628(1985). (08/2006)
DocumentType
Standard
Pages
14
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

1.1 Scope This standard is applicable to x-ray source assemblies and x-ray tube assemblies containing rotating anode x-ray tubes, for use in medical diagnostic radiology for techniques in which the x-ray pattern will be received simultaneously in all points of the image reception area. Unless otherwise specified, this standard is applicable to an x-ray tube assembly with a brand-new rotating anode x-ray tube. This standard does not apply to x-ray source assemblies and x-ray tube assemblies for special applications, when for example steeper variations of the air kerma rate or particular distributions are intended. 1.2 Object This standard describes a method for the determination of the greatest geometrically symmetrical radiation field at a specified distance from the focal spot for which the percentage air kerma rate along the major axes does not fall below a permitted value. Fig. 1 Typical distribution of the relative air kerma rate along the major axis X of a maximum symmetrical radiation field

Standards Relationship
EN 60806:2004 Identical
IEC 60806:1984 Identical
I.S. EN 60806:2004 Identical
NBN EN 60806 : 2005 Identical
NF EN 60806 : 2004 Identical
DIN EN 60806:2006-04 Identical
UNE-EN 60806:2005 Identical

ISO 5-4:2009 Photography and graphic technology — Density measurements — Part 4: Geometric conditions for reflection density
ISO 5-3:2009 Photography and graphic technology — Density measurements — Part 3: Spectral conditions
ISO 5-1:2009 Photography and graphic technology — Density measurements — Part 1: Geometry and functional notation
ISO 5-2:2009 Photography and graphic technology — Density measurements — Part 2: Geometric conditions for transmittance density

$325.41
Including GST where applicable