BS EN 61238-1:2003
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) Test methods and requirements
Hardcopy , PDF
English
11-11-2003
29-07-2022
INTRODUCTION
1 Scope and object
2 Normative references
3 Definitions
4 Symbols
5 General
5.1 Conductor
5.2 Connectors and tooling
5.3 Range of approval
6 Electrical tests
6.1 Installation
6.2 Measurements
6.3 Heat cycle test
6.4 Assessment of results
6.5 Requirements
7 Mechanical tests
7.1 Method
7.2 Requirements
8 Test report
Annex A (normative) Equalizers and their preparation
Annex B (normative) Measurements
Annex C (informative) Recommendations to improve accuracy
of measurement
Annex D (informative) Determination of the value of the
short-circuit-current
Annex E (normative) Calculation method
Annex F (informative) Explanation of the calculation method
Annex G (informative) Explanation of the temperature profile
Annex H (informative) Explanation of the statistical method
of assessing results of tests on
electrical connectors
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Applies to compression and mechanical connectors for power cables for rated voltages up to 30 kV (U[m] = 36 kV), e.g. buried cables or cables installed in buildings, having a) conductors complying with IEC 60228 and IEC 60228A with cross-sectional areas 10 mm[2] and greater for copper and 16 mm[2] and greater for aluminium, b) a maximum continuous conductor temperature not exceeding 90 degree C.
| Committee |
GEL/20/11
|
| DevelopmentNote |
Supersedes BS 4579-1(1970), BS 4579-3(1976) and 99/243122 DC (11/2003)
|
| DocumentType |
Standard
|
| ISBN |
058042751X
|
| Pages |
62
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
This part of IEC 61238 applies to compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV), e.g. buried cables or cables installed in buildings, having conductors complying with IEC 60228 and IEC 60228A with cross-sectional areas 10 mm2 and greater for copper and 16 mm2 and greater for aluminium, a maximum continuous conductor temperature not exceeding 90 °C.
| Standards | Relationship |
| IEC 61238-1:2003 | Identical |
| DIN EN 61238-1 : 2004 | Identical |
| NBN EN 61238-1 : 2004 | Identical |
| I.S. EN 61238-1:2003 | Identical |
| EN 61238-1:2003 | Identical |
| NF EN 61238-1 : 2003 | Identical |
| UNE-EN 61238-1:2006 | Identical |
A newer version of this standard is available.