BS EN 61526:2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Radiation protection instrumentation. Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations. Direct reading personal dose equivalent meters

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-06-2013

Superseded date

09-04-2026

Superseded by

BS EN IEC 61526:2026

$737.91
Including GST where applicable
Summarise this standard

INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Units and list of symbols
5 Mechanical characteristics
6 General characteristics
7 General test procedures
8 Additivity of indicated value
9 Radiation performance requirements and tests
10 Electrical and environmental performance
   requirements and tests
11 Electromagnetic performance requirements
   and tests
12 Mechanical performance, requirements and tests
13 Uncertainty
14 Documentation
15 Operation and maintenance manual
Annex A (normative) - Statistical fluctuations
Annex B (informative) - Procedure to determine the
        variation of the relative response
        due to radiation energy and angle
        of radiation incidence
Annex C (informative) - Usage categories of personal
        dosemeters
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Pertains to personal dose equivalent meters with the following characteristics: a) They are worn on the trunk or the extremities of the body; b) They measure the personal dose equivalents H[p](10) and H[p](0,07) from external X and gamma, neutron and beta radiations, and may measure the personal dose equivalent rates H[p](10) and H[p](0,07) for the same radiations (for alarming purposes); c) They have a digital indication; and d) They may have alarm functions for the personal dose equivalents or personal dose equivalent rates.

Committee
NCE/2
DevelopmentNote
Supersedes BS IEC 61526. (03/2007) Supersedes 00/716716 DC. (06/2007)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This International Standard applies to personal dose equivalent meters with the following characteristics: They are worn on the trunk or the extremities of the body. They measure the personal dose equivalents Hp(10) and Hp(0,07) from external X and gamma, neutron and beta radiations, and may measure the personal dose equivalent rates Hp (10) and Hp (0,07) for the same radiations (for alarming purposes). They have a digital indication. They may have alarm functions for the personal dose equivalents or personal dose equivalent rates. This standard is therefore applicable to the measurement of the following combinations of dose quantities (including the respective dose rates) and radiation Hp(10) and Hp(0,07) from X and gamma radiations; Hp(10) and Hp(0,07) from X, gamma and beta radiations; Hp(10) from X and gamma radiations; Hp(10) from neutron radiations; Hp(10) from X, gamma and neutron radiations; Hp(0,07) from X, gamma and beta radiations. NOTE 1 When reference is made in this standard to ”dose”, this is meant to indicate personal dose equivalent, unless otherwise stated. NOTE 2 When reference is made in this standard to ”dosemeter”, this is meant to include all personal dose equivalent meters, unless otherwise stated. This standard specifies requirements for the dosemeter and, if supplied, for its associated readout system. This standard specifies, for the dosemeters described above, general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. The only requirements specified for associated readout systems are those which affect its accuracy of readout of the personal dose equivalent and alarm settings and those which concern the influence of the reader on the dosemeter. This standard also specifies in Annex C usage categories with respect to different measuring capabilities. This standard does not cover special requirements for accident or emergency dosimetry although the dosemeters may be used for this purpose. The standard does not apply to dosemeters used for measurement of pulsed radiation, such as radiation emanating from most medical diagnostic X-ray facilities, linear accelerators or similar equipment.

Standards Relationship
NF EN 61526 : 2013 Identical
NBN EN 61526 : 2013 Identical
I.S. EN 61526:2013 Identical
DIN EN 61526:2013-09 Identical
EN 61526:2013 Identical
UNE-EN 61526:2013 Equivalent

⚠

A newer version of this standard is available.

View Current Edition
$737.91
Including GST where applicable