BS EN 61557-9:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for insulation fault location in IT systems
Hardcopy , PDF
English
31-03-2017
09-04-2025
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Marking and operating instructions
6 Tests
7 Overview of requirements and tests for IFLSs
Annex A (normative) - Equipment for insulation fault
location in medical locations
Annex B (normative) - Portable equipment for insulation
fault location
Annex C (informative) - Example of an IFLS and explanation
of upstream and downstream system leakage
capacitances
Bibliography
Annex ZA (normative) - Normative references to
international publications with
their corresponding European publications
Defines the requirements for the insulation fault location system (IFLS) which localizes insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1000 V a.c., as well as in unearthed IT d.c. systems with voltages up to 1500 V d.c., independent of the measuring principle. IT systems are described in IEC 60364-4-41 amongst other literature.
| Committee |
PEL/85
|
| DevelopmentNote |
Supersedes 98/200252 DC. (05/2005) Supersedes 12/30274737 DC. (02/2015)
|
| DocumentType |
Standard
|
| Pages |
34
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This part of IEC61557 specifies the requirements for the insulation fault location system (IFLS) which localizes insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1000V a.c., as well as in unearthed IT d.c. systems with voltages up to 1500V d.c., independent of the measuring principle. IT systems are described in IEC60364‑4‑41 amongst other literature. Additional data for a selection of devices in other standards should be noted. NOTE Further information on insulation fault location can be found in the following standards: IEC60364‑4‑41:2005, 411.6, and IEC60364‑5‑53:2001, 531.3.
| Standards | Relationship |
| IEC 61557-9:2014 | Identical |
| NBN EN 61557-9 : 2015 COR 2016 | Identical |
| DIN EN 61557-9 : 2015 COR 1 2017 | Identical |
| I.S. EN 61557-9:2015 | Identical |
| EN 61557-9:2015 | Equivalent |
| UNE-EN 61557-9:2015 | Equivalent |
| UNE-EN 61557-9:2010 | Identical |
A newer version of this standard is available.
View Current Edition