BS EN 62271-110:2005

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

High-voltage switchgear and controlgear Inductive load switching

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

23-03-2006

Superseded date

09-03-2018

Superseded by

BS EN 62271-110:2009

$531.66
Including GST where applicable

Committee
PEL/17
DocumentType
Standard
Pages
30
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Applicable to a.c. circuit-breakers designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1000 V and applied for inductive current switching with or without additional short-circuit current breaking duties. The standard is applicable to circuit-breakers in accordance with IEC 62271-100 that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents. Switching unloaded transformers, i.e. breaking transformer magnetizing current, is not considered in this standard. The reasons for this are as follows: a) due to the non-linearity of the transformer core, it is not possible to correctly model the switching of transformer magnetizing current using linear components in a test laboratory. Tests conducted using an available transformer, such as a test transformer, will only be valid for the transformer tested and cannot be representative for other transformers; b) as detailed in the guide for application of IEC 62271-100 and IEC 60694, the characteristics of this duty are usually less severe than any other inductive current switching duty. It should be noted that such a duty may produce severe overvoltages within the transformer winding(s) depending on the circuit-breaker re ignition behaviour and transformer winding resonance frequencies. Short-line faults, out-of-phase current making and breaking and capacitive current switching are not applicable to circuit-breakers applied to switch shunt reactors or motors. These duties are therefore not included in this standard.

Standards Relationship
EN 62271-110:2005 Equivalent
I.S. EN 62271-110:2005 Equivalent
IEC 62560:2011 Identical
IEC 62271-110:2005 Identical

$531.66
Including GST where applicable