BS EN 868-8:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Packaging for terminally sterilized medical devices Re-usable sterilization containers for steam sterilizers conforming to EN 285. Requirements and test methods
Hardcopy , PDF
English
31-10-2009
09-01-2019
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Information to be supplied by the manufacturer
6 Test methods
Annex A (informative) - Details of significant technical
changes between this European
Standard and the previous edition
Annex B (informative) - Guidance on dimensions
Annex C (normative) - Handle strength test
Annex D (normative) - Stacking test
Annex E (normative) - Stacking device capability test
Annex F (normative) - Determination of sterilization
performance
Annex G (normative) - Load dryness tests
Annex H (informative) - Guidance on determination of useful
life
Bibliography
Gives test methods and values for re-usable containers used as sterile barrier systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
| Committee |
CH/198
|
| DevelopmentNote |
Supersedes 92/58628 DC. (08/2005) Supersedes 07/30167330 DC. (10/2009)
|
| DocumentType |
Standard
|
| Pages |
22
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This part of EN 868 provides test methods and values for re-usable containers used as sterile barrier systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use. These containers are intended to be used in steam sterilizers conforming to EN 285. NOTE 1 The need for a packaging material inside the container is determined by the manufactures and users. This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add nor modify the general requirements specified in EN ISO 11607-1. As such, the particular requirements in 4.2 to 4.5 can be used to demonstrate compliance with one or more but not all of the requirements of EN ISO 11607-1. NOTE 2 When it is intended to use the containers in a steam sterilizer not conforming to EN 285 the sterilization performance of the container in the specific sterilization cycle to be used is validated by the user. Other attributes of the container are also reviewed for compatibility with the sterilizer cycle e.g. operating temperature. NOTE 3 When additional materials are used inside the sterile barrier system in order to ease the organization, drying or aseptic presentation (e.g. inner wrap, container filter, indicators, packing lists, mats, instrument organizer sets, tray liners or an additional envelope around the medical device) then other requirements, including the determination of the acceptability of these materials during validation activities, may apply.
| Standards | Relationship |
| NBN EN 868-8 : 2009 | Identical |
| NF EN 868-8 : 2009 | Identical |
| NS EN 868-8 : 2009 | Identical |
| NEN EN 868-8 : 2009 | Identical |
| DIN EN 868-8:2009-09 | Identical |
| I.S. EN 868-8:2009 | Identical |
| UNE-EN 868-8:2009 | Identical |
| EN 868-8:2009 | Identical |
A newer version of this standard is available.
View Current Edition