BS EN ISO 9170-2:2008
Current
The latest, up-to-date edition.
Terminal units for medical gas pipeline systems Terminal units for anaesthetic gas scavenging systems
Hardcopy , PDF
English
29-08-2008
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
4.1 Safety
4.2 Alternative construction
4.3 Materials
4.4 Design requirements
4.5 Construction requirements
5 Test methods
5.1 General
5.2 Endurance test
5.3 Test method for pressure drop
5.4 Test method for connection force
5.5 Test method for disconnection force
5.6 Tests for mechanical strength
5.7 Tests for leakage
5.8 Test for type specificity
5.9 Test for effective connection of probes to sockets
5.10 Test for connection of receiving or disposal
hoses to hose inserts
5.11 Test for durability of markings and colour coding
6 Marking, colour coding and packaging
6.1 Marking
6.2 Colour coding
6.3 Packaging
7 Information to be supplied by the manufacturer
Annex A (informative) - Rationale
Annex B (informative) - Environmental aspects
Annex C (informative) - Special national and regional
conditions for electrical installations
Annex ZA (informative) - Correspondence between this International
Standard and Directive 93/42/EEC
Bibliography
Describes the requirements and dimensions for terminal units intended for use in anaesthetic gas scavenging disposal systems in accordance with ISO 7396-2.
| Committee |
CH/121/6
|
| DevelopmentNote |
Supersedes BS EN 737-4 and 05/30129368 DC. (09/2008)
|
| DocumentType |
Standard
|
| Pages |
34
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
1.1 This part of ISO 9170 specifies the requirements and dimensions for terminal units intended for use in anaesthetic gas scavenging disposal systems in accordance with ISO 7396-2.
1.2 This part of ISO 9170 specifies two types of terminal unit according to whether the power device is upstream or downstream of the terminal unit.
1.3 This part of ISO 9170 also specifies requirements and dimensions for the mating counterpart (probe) of the type-specific connection point which is part of the terminal unit.
1.4 This part of ISO 9170 does not specify the ranges of nominal operating pressure for terminal units, which are defined in ISO 7396-2.
1.5 This part of ISO 9170 does not specify requirements for terminal units for use with compressed medical gases and vacuum, which are covered in ISO 9170-1.