Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS IEC 61865:2001

Current

Current

The latest, up-to-date edition.

Overhead lines. Calculation of the electrical component of distance between live parts and obstacles. Method of calculation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

29-03-2002

$531.66
Including GST where applicable

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and symbols
   3.1 Definitions
   3.2 Symbols
4 Approach used to derive the electrical distance
5 Overvoltages
   5.1 Classification of overvoltages
   5.2 Temporary overvoltages
   5.3 Slow-front overvoltages
   5.4 Fast-front overvoltages
6 Required withstand voltage of the air gap
   6.1 General
   6.2 Calculation of the required withstand voltage
7 Calculation of the distance associated with the
   overvoltages
Annex A (informative) Relationship between U(50)
        and the gap length, d
Annex B (informative) Example of the calculation of
        the electrical component
Bibliography

Gives guidance for the calculation of electrical distances between live and earthed parts required to prevent air-gap breakdown which may endanger members of the public who legitimately come close to live parts. Applicable only to overhead lines designed to operate at more than 45 kV phase-to-phase a.c. It manages the electrical component of distances between conductors and movable objects - vehicles on the ground, vessels on water, persons on top of objects or on the ground, wildlife on the ground (but not airborne), etc.

Committee
PEL/11
DevelopmentNote
Supersedes 91/34059 DC (04/2002)
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
IEC 61865:2001 Identical

IEC 61472:2013 Live working - Minimum approach distances for a.c. systems in the voltage range 72,5 kV to 800 kV - A method of calculation
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules