BS ISO/IEC 11801-5:2017
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Information technology. Generic cabling for customer premises Data centres
Hardcopy , PDF
English
31-05-2018
14-12-2018
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 Conformance
5 Structure of the generic cabling system
6 Channel performance requirements
7 Link performance requirements
8 Reference implementations
9 Cable requirements
10 Connecting hardware requirements
11 Requirements for cords and jumpers
Annex A (normative) - Combination of balanced cabling
links
Annex B (informative) - Usage of high density connecting
hardware within optical fibre cabling
Annex C (informative) - Examples of structures in
accordance with ISO/IEC 11801-5
Annex D (informative) - Examples of networking
architectures
Bibliography
Describes generic cabling within and to the computer room spaces of data centre premises, or data centre spaces within other types of buildings.
| Committee |
TCT/7
|
| DevelopmentNote |
Supersedes 16/30325955 DC. (12/2017)
|
| DocumentType |
Standard
|
| Pages |
62
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
This part of ISO/IEC 11801 specifies generic cabling within and to the computer room spaces of data centre premises, or data centre spaces within other types of buildings. It covers balanced cabling and optical fibre cabling. This document is optimized for premises in which the maximum distance over which telecommunications services can be distributed is 2 000 m. The principles of this document can also be applied to larger installations. Cabling specified by this document supports a wide range of services including voice, data and video that can also incorporate the supply of power. This document specifies directly or via reference to ISO/IEC 11801-1 the structure and minimum configurations for generic cabling within data centres, the interfaces at the equipment outlet (EO) and the external network interface (ENI), the performance requirements for cabling links and channels, the implementation requirements and options, the performance requirements for cabling components, the conformance requirements and verification procedures. Safety (e.g. electrical safety and protection, fire) and electromagnetic compatibility (EMC) requirements are outside the scope of this document, and are covered by other standards and by regulations. However, information given by this document can be of assistance.
| Standards | Relationship |
| ISO/IEC 11801-5:2017/Cor 1:2018 | Identical |
| ISO/IEC 11801-5:2017 | Equivalent |
This standard has been withdrawn and is no longer current. No replacement edition is available.