Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CEI EN 50107-2 : 2005

Current

Current

The latest, up-to-date edition.

SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 2: REQUIREMENTS FOR EARTH-LEAKAGE AND OPEN-CIRCUIT PROTECTIVE DEVICES

Available format(s)

Hardcopy , PDF

Language(s)

English - Italian

Published date

01-01-2005

$190.73
Including GST where applicable

1 Scope
2 Normative references
3 Definitions
4 General requirements
5 Tests
6 Classification
7 Marking
8 Terminals
9 Provision for protective earthing
10 Protection against accidental contact with live parts
11 Moisture resistance and insulation of type B devices
12 Electric strength
13 Thermal endurance of devices
14 Fault conditions
15 Construction
16 Creepage distances and clearances
17 Screws, current-carrying parts and connections
18 Resistance to heat, fire and tracking
19 Resistance to corrosion
20 Performance
21 Interchangeability
Annex A (normative) - Testing of the response time of
        earth-leakage protective devices
Annex B (informative) - An example method of measuring
        the performance of an earthleakage protective device
Annex C (normative) - Test of the response time of
        open-circuit protective devices
Annex D (informative) - A method of measuring the
        performance of an open-circuit protective device

Defines requirements for earth-leakage and open-circuit protective devices designed to protect circuits for neon tubes operating from transformers conforming to EN 61050 at voltages exceeding 1000 V but not exceeding 10000 V.

Committee
CT 34
DevelopmentNote
Classificazione CEI 34-107. (08/2005)
DocumentType
Standard
Pages
42
PublisherName
Comitato Elettrotecnico Italiano
Status
Current

Standards Relationship
EN 50107-2:2005 Identical

EN 50107-1 : 2002 AMD 1 2004 SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 1: GENERAL REQUIREMENTS
EN 61050:1992/A1:1995 TRANSFORMERS FOR TUBULAR DISCHARGE LAMPS HAVING A NON LOAD OUTPUT VOLTAGE EXCEEDING 1000 V (GENERALLY CALLED NEON TRANSFORMERS - GENERAL AND SAFETY REQUIREMENTS
IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)

$190.73
Including GST where applicable