Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DD ENV 13999-4:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Adhesives. Short term method for measuring the emission properties of low-solvent or solvent-free adhesives after application Determination of volatile diisocyanates

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

12-12-2002

Superseded date

31-05-2007

$325.41
Including GST where applicable

Foreword
1 Scope
2 Normative references
3 Principle
4 Safety
5 Reagents and materials
6 Apparatus
   6.1 Sampler
       6.1.1 Filter holder
       6.1.2 Filter
   6.2 Filtration equipment
   6.3 Sampling pump
   6.4 Tubing
   6.5 Flow meter calibrator
   6.6 High performance liquid chromatograph (HPLC)
7 Procedure
   7.1 Preparation of sampling devices
   7.2 Test chamber air sampling
   7.3 Storage of loaded sampling filters
   7.4 Blanks
   7.5 Analysis
       7.5.1 Cleaning of glassware
       7.5.2 Sample desorption and pre-reaction before HPLC
             analysis
       7.5.3 Preparation of calibration standards
       7.5.4 Calibration of liquid chromatograph
       7.5.5 Analysis of pre-reacted sample solutions
8 Identification and calculation
   8.1 Identification and isocyanates
   8.2 Concentration of analytes in the sampled air
9 Interferences
10 Precision and bias
11 Test report
12 Quality control
Bibliography

Gives a procedure for the determination of volatile organic isocyanates in the exhaust air of an emission test chamber after application of an adhesive.

Committee
PRI/52
DevelopmentNote
Reviewed and confirmed by BSI, October 2005. (10/2005)
DocumentType
Standard
Pages
14
PublisherName
British Standards Institution
RevisionOf
Status
Superseded
SupersededBy

Standards Relationship
ENV 13999-4 : DRAFT 2002 Identical
I.S. ENV 13999-4:2002 Equivalent

EN ISO 16017-1:2000 Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling (ISO 16017-1:2000)
ISO 16017-1:2000 Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling
ISO 16702:2007 Workplace air quality — Determination of total organic isocyanate groups in air using 1-(2-methoxyphenyl)piperazine and liquid chromatography
ENV 13999-1 : DRAFT 2001 ADHESIVES - SHORT TERM METHOD FOR MEASURING THE EMISSION PROPERTIES OF LOW-SOLVENT OR SOLVENT-FREE ADHESIVES AFTER APPLICATION - PART 1: GENERAL PROCEDURE
EN 1232:1997 Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test methods
ENV 13419-1 : DRAFT 99 BUILDING PRODUCTS - DETERMINATION OF THE EMISSION OF VOLATILE ORGANIC COMPOUNDS - PART 1: EMISSION TEST CHAMBER METHOD

$325.41
Including GST where applicable