Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DD ISO/TS 22367 : 2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

MEDICAL LABORATORIES - REDUCTION OF ERROR THROUGH RISK MANAGEMENT AND CONTINUAL IMPROVEMENT

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2008

Superseded date

30-04-2010

Superseded by

DD CEN ISO/TS 22367:2010

$307.09
Including GST where applicable

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Management responsibility in preventive and
   corrective actions, and continual improvement
   4.1 General
   4.2 Management responsibility in preventive actions
   4.3 Management responsibility in corrective actions
   4.4 Management responsibility in continuous improvement
5 Identification of potential and actual laboratory
   non-conformities, errors and incidents
6 Classification of laboratory non-conformities,
   errors and incidents
7 Preventive action and corrective actions
8 Assessment of risk arising from actual and potential
   laboratory non-conformities
9 Review of collected laboratory non-conformities, errors
   and incidents
10 Preventive action and corrective action plans
11 Preventive action and corrective action plan files
12 Continual improvement plan
Annex A (informative) - Failure modes and effects analysis
Annex B (informative) - Model for assessing risk of harm
Annex C (informative) - Ranking of severity levels
Bibliography

Describes the application of ISO 15189 as a system for reducing laboratory error and improving patient safety by applying the principles of risk management, with reference to examination aspects, especially to pre- and post-examination aspects, of the cycle of laboratory medical care.

Committee
CH/212
DevelopmentNote
Renumbered and superseded by DD CEN ISO/TS 22367. (04/2010)
DocumentType
Draft
Pages
20
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
ISO/TS 22367:2008 Identical

IEC 61025:2006 Fault tree analysis (FTA)
IEC 60812:2006 Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA)
ISO 15189:2012 Medical laboratories — Requirements for quality and competence
ISO/IEC Guide 73:2002 Risk management — Vocabulary — Guidelines for use in standards
ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
CLSI GP22 A2 : 2ED 2004 CONTINUOUS QUALITY IMPROVEMENT: INTEGRATING FIVE KEY QUALITY SYSTEM COMPONENTS
ISO 14971:2007 Medical devices — Application of risk management to medical devices
MIL-STD-1629 Revision A:1980 PROCEDURES FOR PERFORMING A FAILURE MODE, EFFECTS AND CRITICALITY ANALYSIS (NO S/S DOCUMENT)
CLSI EP18 A : 1ED 2002 QUALITY MANAGEMENT FOR UNIT-USE TESTING

$307.09